103014754
SRB-E-302FWS-TS
2 Signalling outputs. 2-channel time monitoring. 2 Safety contacts, 1 Safety Output. Detects standstill using 1 or 2 impulse sensors, additional standstill signal, e.g. PLC as second input channel
Product type description: | SRB-E-302FWS-TS |
Article number (order number): | 103014754 |
EAN (European Article Number): | 4030661511276 |
Certificates: | TÜV |
Product name: | SRB-E-302FWS-TS |
Standards: | ISO 13849-1 EN 60947-5-1 EN 60204-1 EN 60947-5-5 IEC 61508 |
Climatic stress: | EN 60068-2-78 |
Enclosure material: | Glass-fibre reinforced thermoplastic, ventilated |
Material of the contacts, electrical: | Ag-Ni, self-cleaning, positive drive |
Weight: | 170 g |
Stop-Category: | 0 |
Electronic Fuse: | Yes |
Wire breakage detection: | Yes |
Short-circuit recognition: | Yes |
Start input: | Yes |
Feedback circuit: | Yes |
Automatic reset function: | Yes |
Reset edge detection: | Yes |
Earth connection detection: | Yes |
Integral System Diagnostics, status: | Yes |
Number of inputs for NC: | 2 |
Number of inputs for NO: | 1 |
Number of LEDs: | 6 |
Number of safety contacts: | 2 |
Number of fail-safe digital outputs: | 1 |
Number of signalling outputs: | 2 |
Standards: | ISO 13849-1 IEC 62061 IEC 61508 |
Mounting: | Snaps onto standard DIN rail to EN 60715 |
Mechanical life, minimum: | 10,000,000 Operations |
Terminal Connector: | Screw connection, plug-in rigid or flexible |
Terminal designations: | IEC 60947-1 |
Cable section, minimum: | 0.25 mm² |
Cable section, maximum: | 2.5 mm² |
Tightening torque of Clips: | 0.5 Nm |
Width: | 22.5 mm |
Height: | 98 mm |
Depth: | 115 mm |
Protection class of the enclosure: | IP40 |
Protection class of the Clearance: | IP54 |
Protection class of Clips or Terminals: | IP20 |
Ambient temperature, minimum: | -25 °C |
Ambient temperature, maximum: | +60 °C |
Storage and transport temperature, minimum: | -40 °C |
Storage and transport temperature, maximum: | +85 °C |
Resistance to vibrations to EN 60068-2-6: | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock: | 30 g / 11 ms |
Rated impulse withstand voltage, relay output: | 4 kV |
Rated impulse withstand voltage, semiconductor output: | 0.8 kV |
Degree of pollution to IEC/EN 60664-1: | 2 |
Rated operating voltage: | 24 VDC -20%/+20%, residual ripple max. 10% |
Operating current: | 125 mA |
Rated AC voltage for controls at DC minimum: | 19.2 VDC |
Rated control voltage at DC, maximum: | 28.8 VDC |
Electrical power consumption: | 3 W |
Contact resistance, maximum: | 0.1 Ω |
Note (Contact resistance): | in new state |
Drop-out delay in case of power failure, typically: | 10 ms |
Drop-out delay in case of emergency, typically: | 10 ms |
Pull-in delay at automatic start, maximum, typically: | 150 ms |
Pull-in delay at automatic start: | Adjustable |
Pull-in delay at RESET, typically: | 150 ms |
Switching frequency, maximum: | 0.3 Hz |
Current leakage: | 1 mA |
Switching capacity, minimum: | 10 VDC |
Switching capacity, minimum: | 10 mA |
Switching capacity, maximum: | 250 VAC |
Switching capacity, maximum: | 6 A |
Conduction resistance, maximum: | 40 Ω |
Switching capacity, maximum: | 24 VDC |
Switching capacity, maximum: | 1 A |
Indicated operating states: | Internal operating voltage Ui |
Note (applications): | safe standstill monitoring Fail-safe delay timer |
ТН ВЭД: | |
Страна происхождения: | DE |
EAN: | |
Вес: | 0,17 kg |
Длина: | 0,00 m |
Ширина: | 0,00 m |
Высота: | 0,00 m |