103003606
RSS260-I1-D-ST
1 x connector plug M8. Thermoplastic enclosure. Frontal and lateral actuation enabled. Individual coding with RFID technology. Max. 31 sensors can be wired in series. Simple mounting without additional angle. Coding level "High" according to ISO 14119. RFID-technology for needs-based protection against, tampering
Product type description: | RSS260-I1-D-ST |
Article number (order number): | 103003606 |
EAN (European Article Number): | 4030661436425 |
eCl@ss number, Version 9.0: | 27-27-24-03 |
Certificates: | TÜV cULus EAC FCC IC |
Product name: | RSS260 |
Standards: | IEC 60947-5-3 |
general information: | Individual coding |
Active principle: | RFID |
Housing construction form: | Block |
Installation conditions (mechanical): | not flush |
Sensor topology: | Sensor for series wiring |
Enclosure material: | Plastic, thermoplastic, self-extinguishing |
Active area: | Glass-fibre, thermoplastic |
Time to readiness, maximum: | 2,000 ms |
Reaction time, maximum: | 100 ms |
Duration of risk, maximum: | 200 ms |
Diagnostic output: | Yes |
Short circuit detection: | Yes |
Short-circuit recognition: | Yes |
Safety functions: | Yes |
Cascadable: | Yes |
Integral System Diagnostics, status: | Yes |
Number of LEDs: | 3 |
Number of semi-conductor outputs with signaling function: | 1 |
Number of fail-safe digital outputs: | 2 |
Standards: | ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 |
Performance Level: | e |
Control category to EN13849: | 4 |
PFH-value: | 6.80 x 10⁻¹⁰ /h |
Safety Integrity Level (SIL): | 3 |
Mission Time: | 20 Year(s) |
Actuating panels: | lateral front side |
Active area: | lateral front |
Ensured switching distance "ON", front: | 10 mm |
Ensured switching distance "ON", side: | 6 mm |
Ensured switching distance "OFF", front: | 18 mm |
Switch distance Sn: | front 12 mm lateral 9 mm |
Hysteresis (Switch distance), maximum: | 2 mm |
Repeat accuracy R R: | 0.5 mm |
Note (Repeat accuracy R): | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm |
Terminal Connector: | Connector M8 |
Note: | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Height of sensor: | 18 mm |
Length of sensor: | 29.5 mm |
Width of sensor: | 39.2 mm |
Protection class: | IP 65 to IEC/EN 60529 IP 67 to IEC/EN 60529 |
Ambient temperature, minimum: | -25 °C |
Ambient temperature, maximum: | +65 °C |
Storage and transport temperature, minimum: | -25 °C |
Storage and transport temperature, maximum: | +85 °C |
Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock: | 30 g / 11 ms |
Rated impulse withstand voltage: | 0.8 kV |
Degree of pollution to VDE 0100: | 3 |
Voltage type: | DC (direct current) |
No-load current: | 100 mA |
Rated operating voltage: | 24 VDC -15% / +10% |
Rated operating voltage, minimum: | 20.4 VDC |
Rated operating voltage, maximum: | 26.4 VDC |
Operating current: | 600 mA |
Required rated short-circuit current to EN 60947-5-1: | 100 A |
Switching frequency, approx.: | 1 Hz |
Current leakage: | 0.5 mA |
Note (LED switching conditions display): | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
PIN 1: | A1 Ue: White |
PIN 2: | X1 safety input 1: Brown |
PIN 3: | A2 GND: Green |
PIN 4: | Y1 safety output 1: Yellow |
PIN 5: | OUT Diagnostic output OUT Grey |
PIN 6: | X2 safety input 2: Pink |
PIN 7: | Y2 safety output 2: Blue |
PIN 8: | IN without function: Red |
Recommendation (actuator): | RST16-1 RST-U-2 RST260-1 |
Ausführung: | p-schaltend |
Spannungsfall Ud, maximum: | 2 V |
Spannung, Gebrauchskategorie DC12: | 24 VDC |
Strom, Gebrauchskategorie DC12: | 0,05 A |
Spannung, Gebrauchskategorie DC13: | 24 VDC |
Strom, Gebrauchskategorie DC13: | 0,05 A |
Störaussendung: | IEC 61000-6-4 |
Störfestigkeit: | IEC 60947-3 |
Hinweis (LED-Zustandsanzeige): | gelbe LED: Betriebszustand grüne LED: Versorgungsspannung rote LED: Fehler |
PIN 1: | A1 Ue: weiß |
PIN 2: | X1 Sicherheitseingang 1: braun |
PIN 3: | A2 GND: grün |
PIN 4: | Y1 Sicherheitsausgang 1: gelb |
PIN 5: | OUT Diagnoseausgang OUT: grau |
PIN 6: | X2 Sicherheitseingang 2: rosa |
PIN 7: | Y2 Sicherheitsausgang 2: blau |
PIN 8: | IN ohne Funktion: rot |
Empfehlung (Betätiger): | RST16-1 RST-U-2 RST260-1 |
Empfehlung Sicherheitsschaltgerät: | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
ТН ВЭД: | |
Страна происхождения: | DE |
EAN: | |
Вес: | 0,06 kg |
Длина: | 0,00 m |
Ширина: | 0,00 m |
Высота: | 0,00 m |