103003602
RSS260-D-ST
1 x connector plug M8. Thermoplastic enclosure. Universal coding with RFID technology. Frontal and lateral actuation enabled. Max. 31 sensors can be wired in series. Simple mounting without additional angle. RFID-technology for needs-based protection against, tampering
Product type description: | RSS260-D-ST |
Article number (order number): | 103003602 |
EAN (European Article Number): | 4030661436418 |
eCl@ss number, Version 9.0: | 27-27-24-03 |
Certificates: | TÜV cULus EAC FCC IC |
Product name: | RSS260 |
Standards: | IEC 60947-5-3 |
general information: | Universal coding |
Active principle: | RFID |
Housing construction form: | Block |
Installation conditions (mechanical): | not flush |
Sensor topology: | Sensor for series wiring |
Enclosure material: | Plastic, thermoplastic, self-extinguishing |
Active area: | Glass-fibre, thermoplastic |
Time to readiness, maximum: | 2,000 ms |
Reaction time, maximum: | 100 ms |
Duration of risk, maximum: | 200 ms |
Diagnostic output: | Yes |
Short circuit detection: | Yes |
Short-circuit recognition: | Yes |
Safety functions: | Yes |
Cascadable: | Yes |
Integral System Diagnostics, status: | Yes |
Number of LEDs: | 3 |
Number of semi-conductor outputs with signaling function: | 1 |
Number of fail-safe digital outputs: | 2 |
Standards: | ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 |
Performance Level: | e |
Control category to EN13849: | 4 |
PFH-value: | 6.80 x 10⁻¹⁰ /h |
Safety Integrity Level (SIL): | 3 |
Mission Time: | 20 Year(s) |
Actuating panels: | lateral front side |
Active area: | lateral front |
Ensured switching distance "ON", front: | 10 mm |
Ensured switching distance "ON", side: | 6 mm |
Ensured switching distance "OFF", front: | 18 mm |
Switch distance Sn: | front 12 mm lateral 9 mm |
Hysteresis (Switch distance), maximum: | 2 mm |
Repeat accuracy R R: | 0.5 mm |
Note (Repeat accuracy R): | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum 100 mm clearance in case of approach from side. |
Terminal Connector: | Connector M8 |
Note: | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Height of sensor: | 18 mm |
Length of sensor: | 29.5 mm |
Width of sensor: | 39.2 mm |
Protection class: | IP 65 to IEC/EN 60529 IP 67 to IEC/EN 60529 |
Ambient temperature, minimum: | -25 °C |
Ambient temperature, maximum: | +65 °C |
Storage and transport temperature, minimum: | -25 °C |
Storage and transport temperature, maximum: | +85 °C |
Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock: | 30 g / 11 ms |
Rated impulse withstand voltage: | 0.8 kV |
Degree of pollution to VDE 0100: | 3 |
Voltage type: | DC (direct current) |
No-load current: | 100 mA |
Rated operating voltage: | 24 VDC -15% / +10% |
Rated operating voltage, minimum: | 20.4 VDC |
Rated operating voltage, maximum: | 26.4 VDC |
Operating current: | 600 mA |
Required rated short-circuit current to EN 60947-5-1: | 100 A |
Switching frequency, approx.: | 1 Hz |
Current leakage: | 0.5 mA |
Note (LED switching conditions display): | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
PIN 1: | A1 Ue: White |
PIN 2: | X1 safety input 1: Brown |
PIN 3: | A2 GND: Green |
PIN 4: | Y1 safety output 1: Yellow |
PIN 5: | OUT Diagnostic output OUT Grey |
PIN 6: | X2 safety input 2: Pink |
PIN 7: | Y2 safety output 2: Blue |
PIN 8: | IN without function: Red |
Recommendation (actuator): | RST16-1 RST-U-2 RST260-1 |
Ausführung: | p-schaltend |
Spannungsfall Ud, maximum: | 2 V |
Spannung, Gebrauchskategorie DC12: | 24 VDC |
Strom, Gebrauchskategorie DC12: | 0,05 A |
Spannung, Gebrauchskategorie DC13: | 24 VDC |
Strom, Gebrauchskategorie DC13: | 0,05 A |
Störaussendung: | IEC 61000-6-4 |
Störfestigkeit: | IEC 60947-3 |
Hinweis (LED-Zustandsanzeige): | gelbe LED: Betriebszustand grüne LED: Versorgungsspannung rote LED: Fehler |
PIN 1: | A1 Ue: weiß |
PIN 2: | X1 Sicherheitseingang 1: braun |
PIN 3: | A2 GND: grün |
PIN 4: | Y1 Sicherheitsausgang 1: gelb |
PIN 5: | OUT Diagnoseausgang OUT: grau |
PIN 6: | X2 Sicherheitseingang 2: rosa |
PIN 7: | Y2 Sicherheitsausgang 2: blau |
PIN 8: | IN ohne Funktion: rot |
Empfehlung (Betätiger): | RST16-1 RST-U-2 RST260-1 |
Empfehlung Sicherheitsschaltgerät: | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
ТН ВЭД: | |
Страна происхождения: | DE |
EAN: | |
Вес: | 0,05 kg |
Длина: | 0,00 m |
Ширина: | 0,00 m |
Высота: | 0,00 m |