Article image KA1485

Rechner Sensors KA1485

KAS-42-39/23-N-D38-PTFE-Z02-1-Leak

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Capacitive. Overfill. Leakage Control. For Containers that contain water-polluting liquids, the Water Resources Act (in Germany WHG) prescribes overfill protection. Also the leak detection sensors, which are placed in the drip trays serve as a, water protection device in accordance with the water protection Act (WHG).

Pliki do pobrania

Parametry techniczne

Thread / Process connection: Ø 38 mm
Housing material active surface: PTFE (FDA 21 CFR 177.1550)
Housing material: PTFE (FDA 21 CFR 177.1550)
Electrical version: 2-Leiter DC
Permitted residual ripple max.: 5%
Frequency of operating cycles max.: 50 Hz
Protective circuit: Eingebaut
Degree of protection IEC 60529: IP 67 (mit versiegelter Potentiometerschraube)
Norm: EN 60947-5-6
Selfinductance (L): 0,2 mH
Selfcapacitance (C): 250 nF
Operating current active surface free: < typ. 1,5 mA
Operating current active surface covered: > typ. 2,5 mA
Sensing dinstance Sn: 2 mm
Operating distance min. / max. adjustable: 0,5…8 mm
Operating voltage: 10…35 V DC
Permitted ambient temperature min.: -25 °C
Permitted ambient temperature max.: +70 °C
Installation: Bündig
Output function: NAMUR
Cable length: 2 m
Connection: PTFE-Kabel, 2 x 0,14 mm², geschirmt
CE: JA
RoHS: JA
MTTF: 1134,55 Jahre
WHG certification: JA
Leakage control certification: Z-65.40-573

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m