813100
KAS-80-26/113-A-G1-PTFE-Z02-1-HP
Electrical connection according to operating manual to get ready for operation – with potentiometer. Capacitive. Overfill. Leakage Control. For Containers that contain water-polluting liquids, the Water Resources Act (in Germany WHG) prescribes overfill protection. Also the leak detection sensors, which are placed in the drip trays serve as a, water protection device in accordance with the water protection Act (WHG).
Thread / Process connection: | G 1" |
Housing material active surface: | PTFE (FDA 21 CFR 177.1550) |
Housing material: | PTFE (FDA 21 CFR 177.1550) |
Housing material lid: | PA |
Electrical version: | 4-Leiter DC |
Operating current (Ie): | 2 x 0…250 mA |
Voltage drop max. (Ud): | ≤ 2 V |
Permitted residual ripple max.: | 10% |
Noload current (Io): | Typ. 15 mA |
Frequency of operating cycles max.: | 50 Hz |
LEDdisplay: | Grün / Gelb |
Protective circuit: | Eingebaut |
Degree of protection IEC 60529: | IP 67 (mit versiegelter Potentiometerschraube) |
Norm: | EN 60947-5-2 |
Media optimized: | JA |
Quattro Protect: | JA |
Sensing dinstance Sn: | produktberuehrend-mediumabhaengig-einstellbar |
Operating distance min. / max. adjustable: | 0…20 mm |
Operating voltage: | 10…35 V DC |
Permitted ambient temperature min.: | -25 °C |
Permitted ambient temperature max.: | +70 °C |
CIP / SIP: | CIP / SIP 121°C |
Installation: | Nichtbündig |
Output function: | Antivalent (S + Ö) |
Output signal: | PNP |
Cable length: | 2 m |
Connection: | PVC-Kabel, 4 x 0,5 mm² |
CE: | JA |
RoHS: | JA |
UL CSA certification: | JA |
MTTF: | 1199 Jahre |
WHG certification: | JA |
Leakage control certification: | Z-65.40-573 |
Overfill prevention certification: | Z-65.13-572 |
ECCN: | |
Kraj pochodzenia: | |
EAN: | |
Waga: | 0,00 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |