1031235
CLOUD IOT GATEWAY
Width: | 22.5 mm |
Height: | 99 mm |
Depth: | 114.5 mm |
Degree of protection: | IP20 |
Ambient temperature (operation): | -25 °C ... 55 °C up to 2000 m above mean sea level |
Ambient temperature (storage/transport): | -25 °C ... 85 °C |
Permissible humidity (operation): | 30 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport): | 5 % ... 95 % |
Air pressure (operation): | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport): | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Shock: | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
Supports cloud computing: | yes |
Cloud platform: | Proficloud |
Weight: | 144.5 g |
Note on weight specifications: | with connectors |
Interface: | RS-232 |
Connection method: | COMBICON connectors |
Interface: | RS-485 |
Number: | 1 |
Connection method: | COMBICON connectors |
Interface: | Ethernet |
Number: | 2 |
Connection method: | RJ45 |
Transmission speed: | 100 Mbps |
Protocols supported: | Modbus/RTU (Master) |
Interface: | Service |
Number: | 1 |
Connection method: | USB type C |
Typical current consumption: | 200 mA |
Supply voltage: | 24 V DC -20 % / +15 % |
Supply voltage range: | 18 V DC ... 30 V DC |
Processor: | Arm® Cortex®-A8 1x 600 MHz |
Realtime clock: | Yes |
Electromagnetic compatibility: | Conformance with EMC Directive 2014/30/EU |
Interference emission: | Noise emission test according to EN 61000-6-3 Class B |
Immunity to surge: | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV |
Immunity to burst: | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV |
Immunity to EF: | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Immunity to ESD: | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
Immunity to conducted interference: | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |
Shock: | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
Shock (operation): | 10g (Bump endurance test according to DIN EN 60068-2-27) |
China RoHS: | Environmentally friendly use period: unlimited = EFUP-e |
eCl@ss 10.0.1: | 27242608 |
eCl@ss 5.1: | 27242608 |
eCl@ss 6.0: | 27242600 |
eCl@ss 7.0: | 27242608 |
eCl@ss 8.0: | 27242608 |
eCl@ss 9.0: | 27242608 |
ETIM 3.0: | EC001604 |
ETIM 4.0: | EC001604 |
ETIM 5.0: | EC001604 |
ETIM 6.0: | EC001604 |
ETIM 7.0: | EC001604 |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,145 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |