580028
ASM2E/1
ASM2E/1 - AS-i safety monitor
Series: | ASM2 |
Functions: | Service button for manual error unlocking and automatic device swap-out of the safe AS-i slaves, Activation/deactivation of function modules, Diagnostics data transfer via AS-Interface, Dynamic contactor monitoring (EDM), selectable, Error unlocking via AS-Interface, Monitoring modules with contact bounce filter, Monitoring modules with contact-simultaneity monitoring, Programmable logic operators, FLIP-FLOP, Programmable logic operators, switch on/off delay, Programmable logic operators, system statuses, Start/restart interlock (RES), selectable, Status LED display for AS-Interface communication, OSSD, start/restart interlock, protective mode, errors, STOP 0 / STOP 1, Support of AS-Interface A/B technology, System signal output |
Number of configurable function modules: | 48 Piece(s) |
Number of programmable logic operators, OR (inputs): | 6 Piece(s) |
Number of programmable logic operators, AND (inputs): | 6 Piece(s) |
Muting function: | No |
Selectable functions for AS-i actuator: | Start/restart interlock (RES), AS-i actuator error unlocking, Dynamic contactor monitoring (EDM) |
SIL: | 3, IEC 61508 |
Performance Level (PL): | e, EN ISO 13849-1 |
Performance Level (PL): | e, EN ISO 13849-1 |
PFHD: | 9.1E-09 per hour |
Category: | 4, EN ISO 13849 |
STOP category: | 0 and 1, IEC/EN 60204-1 |
STOP category: | 0 and 1, IEC/EN 60204-1 |
B10d at AC15 (inductive load): | 100,000 number of cycles, (2 A, 230 V), 250,000 (1 A, 230 V), 540,000 (0.5 A, 230 V) |
B10d at AC15 (inductive load): | 100,000 number of cycles, (2 A, 230 V), 250,000 (1 A, 230 V), 540,000 (0.5 A, 230 V) |
Number of safety monitors, additional text: | With maximum 31 integrated AS-Interface slaves |
Protective circuit: | Short circuit protected, Polarity reversal protection |
Number of safe AS-i switching signals: | 1 Piece(s) |
Number of safe AS-i switching signals: | 1 Piece(s) |
Supply voltage UB: | 24 V, DC, -15 ... 15 % |
Current consumption from AS-i circuit: | 45 mA |
Current consumption from AS-i circuit: | 45 mA |
Fuse: | External with max. 4 A semi time-lag |
Fuse: | External with max. 4 A semi time-lag |
Number of digital switching inputs: | 2 Piece(s) |
Type: | Digital switching input |
Number of safety-related switching outputs (OSSDs): | 1 Piece(s) |
Type: | Digital switching output |
Switching voltage, typ.: | 22 V |
Voltage type: | DC |
System reaction time: | 40 ms |
Readiness delay: | 10 ms |
Readiness delay: | 10 ms |
Function: | Process |
Function: | Process |
AS-i profile: | Monitor 7.F |
Slave address: | 1..31 programmable, default=0 |
Number of connections: | 2 Piece(s) |
Function: | AS-i interface, Signal IN, Signal OUT, Voltage supply |
Type of connection: | Terminal |
Type of terminal: | Screw terminal |
Type of terminal: | Screw terminal |
Function: | Configuration interface |
Function: | Configuration interface |
Designation on device: | CONFIG |
Designation on device: | CONFIG |
Dimension (W x H x L): | 45 mm x 105 mm x 120 mm |
Dimension (W x H x L): | 45 mm x 105 mm x 120 mm |
Net weight: | 420 g |
Net weight: | 420 g |
Housing color: | Black |
Type of fastening: | Snap-on mounting |
Type of configuration: | Software, Teach-in |
Operational controls: | PC software, Control buttons |
Ambient temperature, operation: | -20 ... 60 °C |
Ambient temperature, storage: | -30 ... 70 °C |
Degree of protection: | IP 20, Only suitable for use in electrical operating rooms/cabinets with IP 54 minimum degree of protection. |
Degree of protection: | IP 20, Only suitable for use in electrical operating rooms/cabinets with IP 54 minimum degree of protection. |
Protection class: | III |
Certifications: | AS-i, c TÜV Rheinland US, c UL US, TÜV Rheinland |
Customs tariff number: | 85371098 |
eCl@ss 8.0: | 27371819 |
eCl@ss 8.0: | 27371819 |
ETIM 5.0: | EC001449 |
ETIM 5.0: | EC001449 |
ETIM 6.0: | EC001449 |
ECCN: | |
Kraj pochodzenia: | Deutschland |
EAN: | |
Waga: | 0,40 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |