580024
ASM1E/1
ASM1E/1 - AS-i safety monitor
Series: | ASM1 |
Functions: | Service button for manual error unlocking and automatic device swap-out of the safe AS-i slaves, Activation/deactivation of function modules, Diagnostics data transfer via AS-Interface, Dynamic contactor monitoring (EDM), selectable, Error unlocking via AS-Interface, Monitoring modules with contact bounce filter, Monitoring modules with contact-simultaneity monitoring, Programmable logic operators, FLIP-FLOP, Programmable logic operators, switch on/off delay, Programmable logic operators, system statuses, Start/restart interlock (RES), selectable, Status LED display for AS-Interface communication, OSSD, start/restart interlock, protective mode, errors, STOP 0 / STOP 1, Support of AS-Interface A/B technology, System signal output |
Number of configurable function modules: | 48 Piece(s) |
Number of programmable logic operators, OR (inputs): | 6 Piece(s) |
Number of programmable logic operators, AND (inputs): | 6 Piece(s) |
Muting function: | No |
SIL: | 3, IEC 61508 |
SILCL: | 3, IEC/EN 62061 |
Performance Level (PL): | e, EN ISO 13849-1 |
PFHD: | 9.1E-09 per hour |
Mission time: | 20 years, EN ISO 13849-1 |
Category: | 4, EN ISO 13849 |
STOP category: | 0 and 1, IEC/EN 60204-1 |
B10d at DC13 (inductive load): | 10,000,000 number of cycles, (I < 2 A, 24 V) |
Number of safety monitors per AS-Interface network: | 4 Piece(s) |
Number of safety monitors per AS-Interface network: | 4 Piece(s) |
Protective circuit: | Short circuit protected, Polarity reversal protection |
Supply voltage UB: | 24 V, DC, -15 ... 15 % |
Current consumption, max.: | 150 mA, Without external load |
Current consumption from AS-i circuit: | 45 mA |
Current consumption from AS-i circuit: | 45 mA |
Fuse: | External with max. 4 A semi time-lag |
Fuse: | External with max. 4 A semi time-lag |
Number of digital switching inputs: | 2 Piece(s) |
Type: | Digital switching input |
Number of safety-related switching outputs (OSSDs): | 1 Piece(s) |
Type: | Digital switching output |
Switching voltage, typ.: | 22 V |
Voltage type: | DC |
System reaction time: | 40 ms |
Readiness delay: | 10 ms |
Type: | AS-Interface Safety at Work, RS 232 |
Function: | Process |
Function: | Process |
Slave address: | 1..31 programmable, default=0 |
Slave address: | 1..31 programmable, default=0 |
Number of connections: | 2 Piece(s) |
Function: | AS-i interface, Signal IN, Signal OUT, Voltage supply |
Function: | AS-i interface, Signal IN, Signal OUT, Voltage supply |
Type of connection: | Terminal |
No. of pins: | 12 -pin |
Function: | Configuration interface |
Function: | Configuration interface |
Designation on device: | CONFIG |
Connection cross sections: | 1 x 0.2 to 2.5 mm², wire, 1 x 0.2 to 2.5 mm², wire, 1 x 0.25 to 1 mm², wire with wire-end sleeve, 1 x 0.25 to 2.5 mm², wire with wire-end sleeve, 2 x 0.2 to 1.0 mm², wire, 2 x 0.2 to 1.5 mm², wire, 2 x 0.5 to 1.5 mm², wire with twin wire-end sleeve |
Connection cross sections: | 1 x 0.2 to 2.5 mm², wire, 1 x 0.2 to 2.5 mm², wire, 1 x 0.25 to 1 mm², wire with wire-end sleeve, 1 x 0.25 to 2.5 mm², wire with wire-end sleeve, 2 x 0.2 to 1.0 mm², wire, 2 x 0.2 to 1.5 mm², wire, 2 x 0.5 to 1.5 mm², wire with twin wire-end sleeve |
Housing material: | Plastic, PA 66 |
Net weight: | 350 g |
Housing color: | Black |
Type of fastening: | Snap-on mounting |
Type of display: | LED |
Type of display: | LED |
Type of configuration: | Software, Teach-in |
Ambient temperature, operation: | -20 ... 60 °C |
Ambient temperature, operation: | -20 ... 60 °C |
Degree of protection: | IP 20, Only suitable for use in electrical operating rooms/cabinets with IP 54 minimum degree of protection. |
Degree of protection: | IP 20, Only suitable for use in electrical operating rooms/cabinets with IP 54 minimum degree of protection. |
Certifications: | AS-i, c TÜV Rheinland US, c UL US, TÜV Rheinland |
US patents: | US 6,285,096 B |
US patents: | US 6,285,096 B |
Customs tariff number: | 85371098 |
eCl@ss 9.0: | 27371819 |
eCl@ss 9.0: | 27371819 |
ETIM 5.0: | EC001449 |
ETIM 6.0: | EC001449 |
ECCN: | |
Kraj pochodzenia: | Deutschland |
EAN: | |
Waga: | 0,41 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |