Ifm SD8600

Industrial gas counter. SDR11DGXFRKG/US-100

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Precise measurement of flow, consumption, pressure and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2) and compressed air. Red/green display for clear identification of the acceptable range. Display can be rotated for optimum alignment

Parametry techniczne

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection R 1 DN25
Measuring range: -10...60 °C 14...140 °F
-10...60 °C: 14...140 °F
Application: for industrial applications
Media: Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air
Medium temperature [°C]: -10...60
Min. bursting pressure [bar]: 64
Min. bursting pressure [MPa]: 6.4
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 80
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Inputs: counter reset
Output signal: switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 150; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 14...3750 l/min 0.4...103.7 m/s 0.8...225 m³/h
14...3750 l/min: 0.4...103.7 m/s
Display range: 0...4500 l/min 0...124.4 m/s 0...270 m³/h
0...4500 l/min: 0...124.4 m/s
Resolution: 2 l/min 0.1 m/s 0.1 m³/h
2 l/min: 0.1 m/s
Set point SP: 32...3749 l/min 0.9...103.7 m/s 1.9...224.9 m³/h
32...3749 l/min: 0.9...103.7 m/s
Reset point rP: 14...3730 l/min 0.4...103.2 m/s 0.8...223.8 m³/h
14...3730 l/min: 0.4...103.2 m/s
Analogue start point ASP: 0...3000 l/min 0...83 m/s 0...180 m³/h
0...3000 l/min: 0...83 m/s
Analogue end point AEP: 750...3750 l/min 20.7...103.7 m/s 45...225 m³/h
750...3750 l/min: 20.7...103.7 m/s
Low flow cut-off LFC: 4...40 l/min 0.1...1.1 m/s 0.3...2.4 m³/h
4...40 l/min: 0.1...1.1 m/s
In steps of: 1 l/min 0.1 m/s 0.1 m³/h
1 l/min: 0.1 m/s
Measuring range [bar]: -1...16
Display range [bar]: -1...20
Resolution [bar]: 0.05
Set point SP [bar]: -0.92...16
Reset point rP [bar]: -1...15.92
Analogue start point [bar]: -1...12.8
Analogue end point [bar]: 2.2...16
In steps of [bar]: 0.01
Measuring range: 0...100000000 m³ 0...353146667.2 scf
0...100000000 m³: 0...353146667.2 scf
Display range: 0...100000000 m³ 0...353146667.2 scf
0...100000000 m³: 0...353146667.2 scf
Set point SP: 0.001...10000000 m³ 0.05...353146667.2 scf
0.001...10000000 m³: 0.05...353146667.2 scf
Pulse value: 0.001...10000000 m³ 0.05...353146667.2 scf
0.001...10000000 m³: 0.05...353146667.2 scf
In steps of: 0.0001 m³ 0.005 scf
0.0001 m³: 0.005 scf
Pulse length [s]: 0.007...2
Measuring range: -10...60 °C 14...140 °F
-10...60 °C: 14...140 °F
Display range: -24...74 °C -11.2...165.2 °F
-24...74 °C: -11.2...165.2 °F
Resolution: 0.2 °C 0.5 °F
0.2 °C: 0.5 °F
Set point SP: -9.7...60 °C 14.6...140 °F
-9.7...60 °C: 14.6...140 °F
Reset point rP: -10...59.7 °C 14...139.4 °F
-10...59.7 °C: 14...139.4 °F
Analogue start point: -10...46 °C 14...114.8 °F
-10...46 °C: 14...114.8 °F
Analogue end point: 4...60 °C 39.2...140 °F
4...60 °C: 39.2...140 °F
In steps of: 0.1 °C 0.1 °F
0.1 °C: 0.1 °F
Temperature coefficient [1/K]: ± 0,07 % MW
Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); at medium temperature 23 °C
Repeatability: ± (0,4 % MW + 0,1 % MEW)
Repeatability [% of the final value]: ± 0,2
Characteristics deviation [% of the final value]: < ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K]: ± 0,15
Greatest TEMPCO of the zero point [% MEW / 10 K]: ± 0,25
Accuracy [K]: ± 0,5; (medium flow in the limit area of the flow measurement range)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP [s]: 0...5
Response time [s]: 0.05
Dynamic response T05 / T09 [s]: T09 = 0,5
Parameter setting options: hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 868 d / 00 03 64 h
Profiles: Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO mode: yes
Required master port type: A
Process data analogue: 8
Process data binary: 2
Min. process cycle time [ms]: 7.2
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -20...85
Max. relative air humidity [%]: 90
Protection: IP 65; IP 67
EMC: DIN EN 60947-5-9
Vibration resistance: DIN EN 68000-2-6 5 g (10...2000 Hz)
DIN EN 68000-2-6: 5 g (10...2000 Hz)
MTTF [years]: 183
UL approval: UL Approval no. I012 File number UL E174189
UL Approval no.: I012
File number UL: E174189
Pressure Equipment Directive: Sound engineering practice; can be used for stable gases fluid group 2
Weight [K40]: 1601.9
Materials: PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts): stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connection: threaded connection R 1 DN25
Display: colour display 1,44", 128 x 128 pixels 2 x LED, yellow
Remarks: MW = measured value MEW = Final value of the measuring range Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity For information about installation and operation please see the operating instructions.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 1,60 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m