RMA300
Absolute multiturn encoder with hollow shaft. MULTITURN ENCODER STANDARD LINE
Absolute position traceability even when unpowered. Bearing operating time measurement for efficient maintenance planning. Freely programmable total resolution up to 31 bits. Programmable digital switching input/output. High shock and vibration resistance thanks to magnetic sensing principle
Resolution: | 65536 steps; 32768 revolutions; 31 bit |
Communication interface: | IO-Link |
Shaft design: | hollow shaft open to one side |
Shaft diameter [mm]: | 12 |
Function principle: | absolute |
Revolution type: | multiturn |
Operating voltage [V]: | 18...30 DC; (to PELV) |
Rated insulation voltage [V]: | 30 |
Current consumption [mA]: | < 75 |
Protection class: | III |
Reverse polarity protection: | yes |
Max. power-on delay time [ms]: | 1000 |
Max. revolution electrical [U/min]: | 12000 |
Short-circuit protection: | yes |
Resolution: | 65536 steps; 32768 revolutions; 31 bit |
Accuracy [°]: | 0.1 |
Parameter setting options: | preset; zero point; direction of rotation; rotational speed |
Communication interface: | IO-Link |
Transmission type: | COM3 (230,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 CDV |
Profiles: | Identification and Diagnosis; Switching Signal Channel; Measurement Data Channel (high resolution) |
SIO mode: | no |
Required master port type: | A |
Min. process cycle time [ms]: | 2.3 |
IO-Link process data (cyclical): | function bit length process value 96 device status 4 binary switching information 5 |
function: | bit length |
process value: | 96 |
device status: | 4 |
binary switching information: | 5 |
IO-Link functions (acyclical): | application specific tag; operating hours counter; internal temperature; switching cycles counter |
Supported DeviceIDs: | Type of operation IO-Link device ID Default 1064 d / 0x000428 h |
Type of operation: | IO-Link device ID |
Default: | 1064 d / 0x000428 h |
Note: | For further information please see the IODD PDF file under "Downloads" |
Ambient temperature [°C]: | -40...85 |
Storage temperature [°C]: | -40...85 |
Max. relative air humidity [%]: | 98; (condensation not permissible) |
Protection: | IP 65; (on the housing: IP 67; on the shaft: IP 64) |
EMC: | DIN EN 61000-4-2 ESD 4 kV CD DIN EN 61000-4-3 HF radiated 10 V/m DIN EN 61000-4-4 Burst 2 kV DIN EN 61000-4-6 HF conducted 10 V |
DIN EN 61000-4-2 ESD: | 4 kV CD |
DIN EN 61000-4-3 HF radiated: | 10 V/m |
DIN EN 61000-4-4 Burst: | 2 kV |
DIN EN 61000-4-6 HF conducted: | 10 V |
Vibration resistance: | DIN EN 60068-2-6 10 g / 10...1000 Hz half-sine |
DIN EN 60068-2-6: | 10 g / 10...1000 Hz half-sine |
Shock resistance: | DIN EN 60068-2-27 100 g / 6 ms |
DIN EN 60068-2-27: | 100 g / 6 ms |
Continuous shock resistance: | DIN EN 60068-2-29 10 g / 16 ms half-sine |
DIN EN 60068-2-29: | 10 g / 16 ms half-sine |
Vibration resistance: | 30 g (10...1000 Hz) |
MTTF [years]: | 283 |
Weight [K40]: | 244.9 |
Dimensions [mm]: | Ø 36 / L = 54.2 |
Materials: | flange: aluminium; housing: stainless steel (1.4521 / 444); plug: stainless steel (1.4401 / 316) |
Max. starting torque [Nm]: | 1 |
Reference temperature torque [°C]: | 20 |
Shaft design: | hollow shaft open to one side |
Shaft diameter [mm]: | 12 |
Shaft material: | stainless steel |
Max. shaft load axial (at the shaft end) [N]: | 40 |
Max. shaft load radial (at the shaft end) [N]: | 110 |
Installation depth of shaft [mm]: | 18 |
Max. axial shaft misalignment [mm]: | 0,5 |
Fixing flange: | clamping flange |
ECCN: | |
Kraj pochodzenia: | PL |
EAN: | |
Waga: | 0,24 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |