PM1506
Electronic pressure sensor. PM-2,5-REA12-A-ZVG/US
Robust stainless steel housing for use in the food and beverage industry. Hygienic, flush design. Resistant to high-pressure cleaning with aggressive cleaning agents. High temperature resistance and high protection rating. Integrated temperature measurement via IO-Link
Output signal: | analogue signal; IO-Link |
Measuring range: | -125...2500 mbar -1.82...36.26 psi -12.5...250 kPa |
-125...2500 mbar: | -1.82...36.26 psi |
Process connection: | threaded connection G 1/2 external thread sealing cone |
Special feature: | Gold-plated contacts |
Measuring element: | ceramic-capacitive pressure measuring cell |
Application: | food and beverage industry |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -25...125; (< 1 h: 150) |
Min. bursting pressure: | 50000 mbar 725 psi 5000 kPa |
50000 mbar: | 725 psi |
Pressure rating: | 30000 mbar 435 psi 3000 kPa |
30000 mbar: | 435 psi |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure |
No dead space: | yes |
Operating voltage [V]: | 18...30 DC |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Integrated watchdog: | yes |
Current consumption [mA]: | 3.5...21.5 |
Power-on delay time [s]: | < 1 |
Current consumption [mA]: | < 45 |
Power-on delay time [s]: | < 0.5 |
Total number of outputs: | 2 |
Output signal: | analogue signal; IO-Link |
Analogue current output [mA]: | 4...20; (scalable; 1:5) |
Max. load [Ω]: | 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) |
Short-circuit proof: | yes |
Overload protection: | yes |
Measuring range: | -125...2500 mbar -1.82...36.26 psi -12.5...250 kPa |
-125...2500 mbar: | -1.82...36.26 psi |
Analogue start point: | -125...2000 mbar -1.82...29 psi -12.5...200 kPa |
-125...2000 mbar: | -1.82...29 psi |
Analogue end point: | 375...2500 mbar 5.44...36.26 psi 37.5...250 kPa |
375...2500 mbar: | 5.44...36.26 psi |
In steps of: | 1 mbar 0.02 psi 0.1 kPa |
1 mbar: | 0.02 psi |
Factory setting: | ASP = 0.0 bar AEP = 2500 mbar |
ASP = 0.0 bar: | AEP = 2500 mbar |
Measuring range [°C]: | -25...150 |
Measuring range [°F]: | -13...302 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,5 (DIN EN 61298-2); (incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1 (-25...85 °C); < ± 0,3 (85...150 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,1 (-25...85 °C); < ± 0,3 (85...150 °C) |
Accuracy [K]: | ± 2.5 K + (0.045 x (ambient temperature - medium temperature)) |
Damping for the analogue output dAA [s]: | 0...4 |
Step response time analogue output [ms]: | 30 |
Step response time analogue output [ms]: | 7 |
Dynamic response T05 / T09 [s]: | < 10 / < 25; (DIN EN 60751 water; > 0,9 m/s) |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 1024 d / 00 04 00 h |
Profiles: | Smart Sensor ED2: Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A) |
SIO mode: | no |
Required master port type: | A; (when pin 2 not connected: B) |
Min. process cycle time [ms]: | 4.5 |
IO-Link resolution pressure [mbar]: | 0.5 |
IO-Link resolution temperature [K]: | 0.2 |
IO-Link process data (cyclical): | function bit length pressure 16 temperature 16 device status 4 |
function: | bit length |
pressure: | 16 |
temperature: | 16 |
device status: | 4 |
IO-Link functions (acyclical): | application specific tag; internal temperature |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 68; IP 69K |
EMC: | DIN EN 61326-1 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 322 |
UL approval: | UL Approval no. J024 File number UL E174189 |
UL Approval no.: | J024 |
File number UL: | E174189 |
Weight [g]: | 252.2 |
Materials: | stainless steel (1.4404 / 316L); PTFE; FKM |
Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PEEK; PTFE |
Min. pressure cycles: | 100 million |
Tightening torque [Nm]: | 20 |
Process connection: | threaded connection G 1/2 external thread sealing cone |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,31 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |