MVQ201
Position sensor for valve actuators. SVS SOLENOID OUT
Reduced wiring due to direct control of the control valve. Self-diagnostics regarding wear, blockages or deposits for preventive maintenance. End position setting with just one click for quick set-up. LED flash mode for a fast visual localisation of the sensor
Electrical design: | PNP |
Output function: | 2 x normally open / normally closed; (selectable) |
Communication interface: | IO-Link |
Housing: | rectangular |
Dimensions [mm]: | 95 x 50 x 57 |
Output function: | 2 x normally open |
Operating principle: | magnetic |
Application: | angle of rotation detection absolute |
Operating voltage [V]: | 10...30 DC |
Current consumption [mA]: | < 40 |
Protection class: | III |
Reverse polarity protection: | yes |
Max. power-on delay time [ms]: | 300 |
Number of inputs and outputs: | Number of digital inputs: 1; Number of digital outputs: 2 |
Number of digital inputs: | 1 |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | 2 x normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Max. current load per output [mA]: | 100 |
Short-circuit protection: | yes |
Overload protection: | yes |
Output function: | 2 x normally open |
Max. current load per output [mA]: | 200 |
Short-circuit protection: | yes |
Overload protection: | yes |
Detection zone [°]: | 360 |
Accuracy [°]: | ± 1 |
Resolution [°]: | 0.1 |
Tolerance [°]: | 0.1...15; (Default 10) |
Hysteresis [°]: | 0.1...5; (Default 3) |
Temperature drift [°/K]: | 0,02 |
Repeatability [°]: | 0,1 |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 CDV |
IO-Link device ID: | 595d / 00 02 53h |
Profiles: | Smart Sensor: Device Identification; Device Diagnosis; Device Teach Channel; Binary Data Channel; Process Data Variable; Blob; Measurement Data Channel |
SIO mode: | yes |
Required master port type: | A |
Min. process cycle time [ms]: | 4 |
Ambient temperature [°C]: | -25...70 |
Protection: | IP 65; IP 67; (Target puck area dust-protected) |
EMC: | EN 61000-4-2 4 kV CD / 8 kV AD EN 61000-4-3 10 V/m EN 61000-4-4 2 kV EN 61000-4-6 10 V EN 55011 class B |
EN 61000-4-2: | 4 kV CD / 8 kV AD |
EN 61000-4-3: | 10 V/m |
EN 61000-4-4: | 2 kV |
EN 61000-4-6: | 10 V |
EN 55011: | class B |
Vibration resistance: | EN 60068-2-6 |
Shock resistance: | EN 60068-2-27 |
MTTF [years]: | 363 |
UL approval: | UL Approval no. S002 |
UL Approval no.: | S002 |
Weight [g]: | 192 |
Housing: | rectangular |
Dimensions [mm]: | 95 x 50 x 57 |
Materials: | PA; plug: stainless steel |
Tightening torque [Nm]: | 3 |
Display: | operation 1 x LED, green switching status 2 x LED, white 1 x LED, RGB |
operation: | 1 x LED, green |
switching status: | 2 x LED, white |
Accessories (supplied): | socket head screws: 4 x M5 x 20, stainless steel target puck |
Pack quantity: | 1 pcs. |
Operating mode: | 12 V |
Switching level high: | 6...30 V |
Switching level low: | 0...2 V |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,19 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |