Ifm AL1400

IO-Link master with PROFINET interface. IO-Link Master PFL PN 4P IP67

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

IO-Link master developed according to AIDA specifications of the automotive manufacturers. Daisy-chain power supply with standardised L-coded M12 connection technology. Configurable current limitation for each port to ensure safe operation. Voltage and current measurement per port for energy monitoring. Connection of actuators up to 2 A

Parametry techniczne

Application: I/O modules for field applications
Daisy-chain function: voltage supply; fieldbus interface
Operating voltage [V]: 20...30 DC; (US; to SELV/PELV)
Current consumption [mA]: 300...3900; (US)
Protection class: III
Additional voltage supply [V]: 20...30 DC; (UA)
Max. current load total [A]: 8
Current rating per port [A]: 2; (adjustable: 0...2; Factory setting: 2)
Max. current load total [A]: 3.6
Current rating per port [A]: 2; (adjustable: 0...2; Factory setting: 0,45)
Total number of inputs and outputs: 8; (configurable)
Number of inputs and outputs: Number of digital inputs: 4; Number of digital outputs: 8
Number of digital inputs: 4; (IO-Link Port Class B: 4 x 1)
Switching level high [V]: 11...30
Switching level low [V]: 0...5
Digital inputs protected against short circuits: yes
Number of digital outputs: 8; (IO-Link Port Class B: 4 x 2)
Short-circuit proof: yes
Max. current load per output [mA]: 2000
Max. current load per output [mA]: 2000
Communication interface: Ethernet; IO-Link
Transmission standard: 10Base-T; 100Base-TX
Transmission rate: 10; 100
Protocol: PROFINET
Factory settings: IP address: 0.0.0.0 subnet mask: 0.0.0.0 gateway IP address: 0.0.0.0 MAC address: see type label
Note on interfaces: CC-C (Conformance Class C); S2-Redundanz; Configuration in Run (CiR); IRT-Fähigkeit; SNMP
Transmission type: COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud)
IO-Link revision: 1.1
Number of ports class B: 4
Ambient temperature [°C]: -25...60
Storage temperature [°C]: -25...85
Max. relative air humidity [%]: 90
Protection: IP 65; IP 66; IP 67
Degree of soiling: 2
EMC: EN 61000-6-2 EN 61000-6-4
Shock resistance: DIN EN 60068-2-27
Vibration resistance: DIN EN 60068-2-64 2009-04 DIN EN 60068-2-6 2008-10
Weight [g]: 308.1
Materials: housing: PA; socket: brass nickel-plated
Remarks: For further information please see the operating instructions.
Pack quantity: 1 pcs.
IN / OUT XF1, XF2: Connector: M12
IO-Link Port Class B X1...X4: Connector: M12
XD1: Connector: M12
XD2: Connector: M12

Parametry logistyczne

ECCN:
Kraj pochodzenia: PL
EAN:
Waga: 0,31 kg
Długość: 0,00 m
Szerokość: 0,00 m