X5.2M12AR-D
Position control for doors / casings on hazardous machinery. Contactless encoded electronic sensor with relay. Category 3 total safety management without an external controller. Suitable for groove profiles and single or double doors
Level of performance without an external controller: | PL = d Level of performance with AWAX controller up to PL = e Safety category without an external controller 3 Safety Integrity Level SIL 2 Cycle before dangerous failure B10d = 2,000,000 at 2A Max. activation distance 8 mm, 3 mm hysteresis Safety contacts/diagnostics 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding mono-code inviolable Indicator LED indicates code recognition Reset automatic (SR version) or Manual (AR version) Attachment 4 tamper-proof M4 screws (optional ref BH4). Suitable for grooved profiles. Screw caps provided. Mounting position 1 Material Polycarbonate Electrical connection 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance IP 67/68 Temperature -25°C to +60°C Marking screen printed + serial no. for traceability Certification TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 |
ECCN: | |
Kraj pochodzenia: | |
EAN: | |
Waga: | 0,00 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |