Position control for doors / casings on hazardous machinery. Contactless encoded electronic sensor with relay. Category 3 total safety management without an external controller. 12V version for embedded applications
Level of performance without an external controller: | PL = c Level of performance with AWAX controller up to PL = e Safety category without an external controller 1 Cycle before dangerous failure B10d = 2,000,000 at 50mA Max. activation distance 10 mm, 2 mm hysteresis Safety contacts 2 x NO 250 mA/48V redundant Detection encoding mono-code inviolable Indicator LED indicates code recognition Reset automatic Attachment 4 tamper-proof M3 screws (optional ref BH3) Mounting position 2 (double wall brackets) Material PA6 Electrical Connection 3, 6, 12m cable (UL2464 PVC) Water resistance IP 68 Temperature -20°C to +60°C Marking pad printing + serial no. for traceability |