Article image KL4112

Beckhoff KL4112

KL4112 | 2-channel analog output terminal 0…20 mA

Bajo pedido. Envíenos un correo electrónico para consultar el precio y la disponibilidad.
"ucnguBrctvdgcxgt0eqo"

Descripción

The KL4112 analog output terminal generates analog output signals in the range from 0 to 20 mA. The power is supplied to the process level with a resolution of 16 bits (default: 15 bits), and is electrically isolated. Ground potential for the output channels of a Bus Terminal is common with the 24 V DC supply. The output stages are powered by the 24 V supply. The two run LEDs give an indication of the data exchange with the Bus Coupler.

Parámetros técnicos

Technology: single-ended
Number of outputs: 2
Power supply: 24 V DC via power contacts (alternative 15 V DC with power supply terminal KL9515)
Signal current: 0…20 mA
Load: < 500 Ω
Output error: < ±0.1 % (relative to end value)
Resolution: 15 bit, configurable to 16 bit
Conversion time: ~ 3.5 ms
Electrical isolation: 500 V (K-bus/signal voltage)
Current consumption power contacts: typ. 50 mA + load
Current consumption K-bus: typ. 60 mA
Bit width in the process image: output: 2 x 16 bit data (2 x 8 bit control/status optional)
Configuration: no address or configuration setting
Special features: increased resolution
Weight: approx. 80 g
Operating/storage temperature: 0…+55 °C/-25…+85 °C
Relative humidity: 95 %, no condensation
Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos.: IP 20/variable
Pluggable wiring: for all KSxxxx Bus Terminals
Approvals: CE, UL, Ex

Parámetros logísticos

ECCN:
País de origen:
EAN:
Peso: 0,00 kg
Longitud: 0,00 m
Anchura: 0,00 m