Connector M12, 8-pole. Thermoplastic enclosure. E-STOP with electronic OSSDs, slender shock-proof enclosure. Device version for connection to a. Safety-Field-Box SFB. Integrated FB interface for command and signaling, devices, to be fitted to commercial-off-the-shelf aluminium, profiles

Technical parameters

Product type description: BDF200-FB-NH-LT-LT-LT-2875
Article number (order number): 103015447
EAN (European Article Number): 4030661509648
eCl@ss number, Version 9.0: 27-33-02-04
Certificates: TÜV cULus EAC
Product name: BDF 200-FB
Standards: IEC 60947-5-1 ISO 13849-1 IEC 61508 IEC 60947-5-5 ISO 13850
Climatic stress: IEC 60947-5-5
Terminal (mechanical): Connector plug M12, 8-pole, A-coded
Enclosure material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Weight: 340 g
Reaction time, maximum: 50 ms
Duration of risk, maximum: 100 ms
Positions used, position 1: NH, Emergency stop
Positions used, position 2: LT-2875, Illuminated pushbutton
Positions used, position 3: LT-2875, Illuminated pushbutton
Positions used, position 4: LT-2875, Illuminated pushbutton
Serial diagnostics: Yes
Safety functions: Yes
Standards: ISO 13849-1 IEC 61508
Performance Level: e
Control category to EN13849: 4
PFH-value: 2.89 x 10⁻¹⁰ /h
Note (PFH-value): up to max. 5,000 switching cycles/year
Safety Integrity Level (SIL): 3
Mission Time: 20 Year(s)
Mechanical life, Emergency-Stop button: 100,000 Operations
Mechanical life, Command devices: 1,000,000 Operations
Width: 40 mm
Height: 69 mm
Length x Width x Height: Depth: 233.5 - 252.5 mm (without and with indicator lamp)
Protection class: IP64
Ambient temperature, minimum: -25 °C
Ambient temperature, maximum: +65 °C
Storage and transport temperature, minimum: -25 °C
Storage and transport temperature, maximum: +85 °C
Resistance to vibrations to EN 60068-2-6: 10 … 150 Hz, amplitude 0.35 mm / 5 g
Restistance to shock: 30 g / 11 ms
Rated impulse withstand voltage: 0.8 kV
Degree of pollution to VDE 0100: 3
Current consumption at 24V: 5 mA
No-load current: 35 mA
Rated operating voltage: 24 VDC −15 % / +10 % (PELV to IEC 60204-1)
Operating current: 150 mA 600 mA
Required rated short-circuit current to EN 60947-5-1: 100 A
Utilisation category DC-12: 24 VDC
Utilisation category DC-12: 0.25 A
Utilisation category DC-13: 24 VDC
Utilisation category DC-13: 0.25 A
Inputs, Switching thresholds: −3 V … 5 V (Low) 15 V … 30 V (High)
Rated operating current (safety outputs): 250 mA
Current leakage: 0.5 mA
Diagnostic output: short-circuit proof, p-type
Spannungsfall Ud, maximum: 1 V
Reststrom: 0,5 mA
Diagnoseausgang: kurzschlussfest, p-schaltend

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.28 kg