Article image 103014754

Schmersal 103014754

SRB-E-302FWS-TS

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

2 Signalling outputs. 2-channel time monitoring. 2 Safety contacts, 1 Safety Output. Detects standstill using 1 or 2 impulse sensors, additional standstill signal, e.g. PLC as second input channel

Technical parameters

Product type description: SRB-E-302FWS-TS
Article number (order number): 103014754
EAN (European Article Number): 4030661511276
Certificates: TÜV
Product name: SRB-E-302FWS-TS
Standards: ISO 13849-1 EN 60947-5-1 EN 60204-1 EN 60947-5-5 IEC 61508
Climatic stress: EN 60068-2-78
Enclosure material: Glass-fibre reinforced thermoplastic, ventilated
Material of the contacts, electrical: Ag-Ni, self-cleaning, positive drive
Weight: 170 g
Stop-Category: 0
Electronic Fuse: Yes
Wire breakage detection: Yes
Short-circuit recognition: Yes
Start input: Yes
Feedback circuit: Yes
Automatic reset function: Yes
Reset edge detection: Yes
Earth connection detection: Yes
Integral System Diagnostics, status: Yes
Number of inputs for NC: 2
Number of inputs for NO: 1
Number of LEDs: 6
Number of safety contacts: 2
Number of fail-safe digital outputs: 1
Number of signalling outputs: 2
Standards: ISO 13849-1 IEC 62061 IEC 61508
Mounting: Snaps onto standard DIN rail to EN 60715
Mechanical life, minimum: 10,000,000 Operations
Terminal Connector: Screw connection, plug-in rigid or flexible
Terminal designations: IEC 60947-1
Cable section, minimum: 0.25 mm²
Cable section, maximum: 2.5 mm²
Tightening torque of Clips: 0.5 Nm
Width: 22.5 mm
Height: 98 mm
Depth: 115 mm
Protection class of the enclosure: IP40
Protection class of the Clearance: IP54
Protection class of Clips or Terminals: IP20
Ambient temperature, minimum: -25 °C
Ambient temperature, maximum: +60 °C
Storage and transport temperature, minimum: -40 °C
Storage and transport temperature, maximum: +85 °C
Resistance to vibrations to EN 60068-2-6: 10 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock: 30 g / 11 ms
Rated impulse withstand voltage, relay output: 4 kV
Rated impulse withstand voltage, semiconductor output: 0.8 kV
Degree of pollution to IEC/EN 60664-1: 2
Rated operating voltage: 24 VDC -20%/+20%, residual ripple max. 10%
Operating current: 125 mA
Rated AC voltage for controls at DC minimum: 19.2 VDC
Rated control voltage at DC, maximum: 28.8 VDC
Electrical power consumption: 3 W
Contact resistance, maximum: 0.1 Ω
Note (Contact resistance): in new state
Drop-out delay in case of power failure, typically: 10 ms
Drop-out delay in case of emergency, typically: 10 ms
Pull-in delay at automatic start, maximum, typically: 150 ms
Pull-in delay at automatic start: Adjustable
Pull-in delay at RESET, typically: 150 ms
Switching frequency, maximum: 0.3 Hz
Current leakage: 1 mA
Switching capacity, minimum: 10 VDC
Switching capacity, minimum: 10 mA
Switching capacity, maximum: 250 VAC
Switching capacity, maximum: 6 A
Conduction resistance, maximum: 40 Ω
Switching capacity, maximum: 24 VDC
Switching capacity, maximum: 1 A
Indicated operating states: Internal operating voltage Ui
Note (applications): safe standstill monitoring Fail-safe delay timer

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.17 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m