103003602
RSS260-D-ST
1 x connector plug M8. Thermoplastic enclosure. Universal coding with RFID technology. Frontal and lateral actuation enabled. Max. 31 sensors can be wired in series. Simple mounting without additional angle. RFID-technology for needs-based protection against, tampering
| Product type description: | RSS260-D-ST | 
| Article number (order number): | 103003602 | 
| EAN (European Article Number): | 4030661436418 | 
| eCl@ss number, Version 9.0: | 27-27-24-03 | 
| Certificates: | TÜV cULus EAC FCC IC | 
| Product name: | RSS260 | 
| Standards: | IEC 60947-5-3 | 
| general information: | Universal coding | 
| Active principle: | RFID | 
| Housing construction form: | Block | 
| Installation conditions (mechanical): | not flush | 
| Sensor topology: | Sensor for series wiring | 
| Enclosure material: | Plastic, thermoplastic, self-extinguishing | 
| Active area: | Glass-fibre, thermoplastic | 
| Time to readiness, maximum: | 2,000 ms | 
| Reaction time, maximum: | 100 ms | 
| Duration of risk, maximum: | 200 ms | 
| Diagnostic output: | Yes | 
| Short circuit detection: | Yes | 
| Short-circuit recognition: | Yes | 
| Safety functions: | Yes | 
| Cascadable: | Yes | 
| Integral System Diagnostics, status: | Yes | 
| Number of LEDs: | 3 | 
| Number of semi-conductor outputs with signaling function: | 1 | 
| Number of fail-safe digital outputs: | 2 | 
| Standards: | ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 | 
| Performance Level: | e | 
| Control category to EN13849: | 4 | 
| PFH-value: | 6.80 x 10⁻¹⁰ /h | 
| Safety Integrity Level (SIL): | 3 | 
| Mission Time: | 20 Year(s) | 
| Actuating panels: | lateral front side | 
| Active area: | lateral front | 
| Ensured switching distance "ON", front: | 10 mm | 
| Ensured switching distance "ON", side: | 6 mm | 
| Ensured switching distance "OFF", front: | 18 mm | 
| Switch distance Sn: | front 12 mm lateral 9 mm | 
| Hysteresis (Switch distance), maximum: | 2 mm | 
| Repeat accuracy R R: | 0.5 mm | 
| Note (Repeat accuracy R): | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum 100 mm clearance in case of approach from side. | 
| Terminal Connector: | Connector M8 | 
| Note: | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current | 
| Height of sensor: | 18 mm | 
| Length of sensor: | 29.5 mm | 
| Width of sensor: | 39.2 mm | 
| Protection class: | IP 65 to IEC/EN 60529 IP 67 to IEC/EN 60529 | 
| Ambient temperature, minimum: | -25 °C | 
| Ambient temperature, maximum: | +65 °C | 
| Storage and transport temperature, minimum: | -25 °C | 
| Storage and transport temperature, maximum: | +85 °C | 
| Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 1 mm | 
| Restistance to shock: | 30 g / 11 ms | 
| Rated impulse withstand voltage: | 0.8 kV | 
| Degree of pollution to VDE 0100: | 3 | 
| Voltage type: | DC (direct current) | 
| No-load current: | 100 mA | 
| Rated operating voltage: | 24 VDC -15% / +10% | 
| Rated operating voltage, minimum: | 20.4 VDC | 
| Rated operating voltage, maximum: | 26.4 VDC | 
| Operating current: | 600 mA | 
| Required rated short-circuit current to EN 60947-5-1: | 100 A | 
| Switching frequency, approx.: | 1 Hz | 
| Current leakage: | 0.5 mA | 
| Note (LED switching conditions display): | LED yellow: Operating condition LED green: Supply voltage LED red: Fault | 
| PIN 1: | A1 Ue: White | 
| PIN 2: | X1 safety input 1: Brown | 
| PIN 3: | A2 GND: Green | 
| PIN 4: | Y1 safety output 1: Yellow | 
| PIN 5: | OUT Diagnostic output OUT Grey | 
| PIN 6: | X2 safety input 2: Pink | 
| PIN 7: | Y2 safety output 2: Blue | 
| PIN 8: | IN without function: Red | 
| Recommendation (actuator): | RST16-1 RST-U-2 RST260-1 | 
| Ausführung: | p-schaltend | 
| Spannungsfall Ud, maximum: | 2 V | 
| Spannung, Gebrauchskategorie DC12: | 24 VDC | 
| Strom, Gebrauchskategorie DC12: | 0,05 A | 
| Spannung, Gebrauchskategorie DC13: | 24 VDC | 
| Strom, Gebrauchskategorie DC13: | 0,05 A | 
| Störaussendung: | IEC 61000-6-4 | 
| Störfestigkeit: | IEC 60947-3 | 
| Hinweis (LED-Zustandsanzeige): | gelbe LED: Betriebszustand grüne LED: Versorgungsspannung rote LED: Fehler | 
| PIN 1: | A1 Ue: weiß | 
| PIN 2: | X1 Sicherheitseingang 1: braun | 
| PIN 3: | A2 GND: grün | 
| PIN 4: | Y1 Sicherheitsausgang 1: gelb | 
| PIN 5: | OUT Diagnoseausgang OUT: grau | 
| PIN 6: | X2 Sicherheitseingang 2: rosa | 
| PIN 7: | Y2 Sicherheitsausgang 2: blau | 
| PIN 8: | IN ohne Funktion: rot | 
| Empfehlung (Betätiger): | RST16-1 RST-U-2 RST260-1 | 
| Empfehlung Sicherheitsschaltgerät: | PROTECT PSC1 SRB-E-301ST SRB-E-201LC | 
| ECCN: | |
| Country of Origin: | DE | 
| EAN: | |
| Weight: | 0.05 kg | 
| Length: | 0.00 m | 
| Width: | 0.00 m | 
| Height: | 0.00 m |