101213954
RSS 36-D-ST
Actuation from side. Thermoplastic enclosure. 27 mm x 108.2 mm x 35 mm. Misaligned actuation possible. 1 x connector socket M12, 8-pole. Universal coding with RFID technology. Max. 31 sensors can be wired in series. 2 short-circuit proof PNP safety outputs. High repeat accuracy of the switching points. RFID-technology for needs-based protection against, tampering. Integral cross-short, wire-breakage and external, voltage monitoring of the safety cables up to the, control cabinet
Product type description: | RSS 36-D-ST |
Article number (order number): | 101213954 |
EAN (European Article Number): | 4030661410623 |
eCl@ss number, Version 9.0: | 27-27-24-03 |
Certificates: | TÜV cULus ECOLAB EAC FCC IC |
Product name: | RSS 36 |
Standards: | IEC 60947-5-3 |
general information: | Universal coding |
Active principle: | RFID |
Housing construction form: | Block |
Installation conditions (mechanical): | not flush |
Sensor topology: | Sensor for series wiring |
Enclosure material: | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Active area: | Glass-fibre, reinforced thermoplastic |
Time to readiness, maximum: | 2,000 ms |
Reaction time, maximum: | 100 ms |
Duration of risk, maximum: | 200 ms |
Diagnostic output: | Yes |
Short circuit detection: | Yes |
Short-circuit recognition: | Yes |
Safety functions: | Yes |
Cascadable: | Yes |
Integral System Diagnostics, status: | Yes |
Number of LEDs: | 3 |
Number of semi-conductor outputs with signaling function: | 1 |
Number of fail-safe digital outputs: | 2 |
Standards: | ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 |
Performance Level: | e |
Control category to EN13849: | 4 |
PFH-value: | 2.70 x 10⁻¹⁰ /h |
Safety Integrity Level (SIL): | 3 |
Mission Time: | 20 Year(s) |
Actuating panels: | lateral |
Active area: | lateral |
Mounting: | A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used. |
Switch distance: | 12 mm |
Ensured switch distance "ON" Sao: | 10 mm |
Ensured switch distance "OFF" Sar: | 20 mm |
Hysteresis (Switch distance), maximum: | 2 mm |
Repeat accuracy R R: | 0.5 mm |
Note (Repeat accuracy R): | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm. |
Terminal Connector: | Connector M12, 8-pole |
Note: | The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current |
Height of sensor: | 25 mm |
Length of sensor: | 22 mm |
Width of sensor: | 106.3 mm |
Protection class: | IP 65 to IEC/EN 60529 IP 67 to IEC/EN 60529 IP 69 to IEC/EN 60529 |
Ambient temperature, minimum: | -25 °C |
Ambient temperature, maximum: | +70 °C |
Storage and transport temperature, minimum: | -25 °C |
Storage and transport temperature, maximum: | +85 °C |
Material temperature resistance of the cable (in motion), minimum: | -10 °C |
Material temperature resistance of the cable (at rest), minimum: | -30 °C |
Material temperature resistance (long-term), maximum: | +105 °C |
Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock: | 30 g / 11 ms |
Rated impulse withstand voltage: | 0.8 kV |
Degree of pollution to VDE 0100: | 3 |
Voltage type: | DC (direct current) |
No-load current: | 100 mA |
Rated operating voltage: | 24 VDC −15 % / +10 % |
Rated operating voltage, minimum: | 20.4 VDC |
Rated operating voltage, maximum: | 26.4 VDC |
Operating current: | 600 mA |
Required rated short-circuit current to EN 60947-5-1: | 100 A |
Switching frequency, approx.: | 1 Hz |
Rated operating current (safety outputs): | 250 mA |
Output current, (fail-safe output), maximum: | 0.25 A |
Current leakage: | 0.5 mA |
Note (LED switching conditions display): | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
PIN 1: | A1 Ue Brown |
PIN 2: | X1 Safety input 1 White |
PIN 3: | A2 GND Blue |
PIN 4: | Y1 Safety output 1 Black |
PIN 5: | OUT Diagnostic output OUT Grey |
PIN 6: | X2 Safety input 2 violet |
PIN 7: | Y2 Safety output 2 red |
PIN 8: | IN without function Pink |
Included in delivery: | Actuators must be ordered separately. |
Recommendation (actuator): | RST 36-1 RST 36-1-R |
Note (General): | Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. Short-circuit recognition by the evaluation is not necessary. |
Strom, Gebrauchskategorie DC12: | 0,05 A |
Spannung, Gebrauchskategorie DC13: | 24 VDC |
Strom, Gebrauchskategorie DC13: | 0,05 A |
Störaussendung: | IEC 61000-6-4 |
Störfestigkeit: | IEC 60947-3 |
Hinweis (LED-Zustandsanzeige): | gelbe LED: Betriebszustand grüne LED: Versorgungsspannung rote LED: Fehler |
PIN 1: | A1 Ue: braun |
PIN 2: | X1 Sicherheitseingang 1: weiß |
PIN 3: | A2 GND: blau |
PIN 4: | Y1 Sicherheitsausgang 1: schwarz |
PIN 5: | OUT Diagnoseausgang OUT: grau |
PIN 6: | X2 Sicherheitseingang 2: violett |
PIN 7: | Y2 Sicherheitsausgang 2: rot |
PIN 8: | IN ohne Funktion: rosa |
Lieferumfang: | Die Betätiger sind nicht im Lieferumfang enthalten. |
Empfehlung (Betätiger): | RST 36-1 RST 36-1-R |
Empfehlung Sicherheitsschaltgerät: | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Hinweis (Allgemein): | Anforderungen an die Auswertung: Zweikanaliger Sicherheitseingang, geeignet für p-schaltende Sensoren mit Schließerfunktion. Die Funktionstests der Sensoren mit zyklischem Abschalten der Sensorausgänge für max. 2 ms müssen von der Auswertung toleriert werden. Eine Querschlusserkennung in der Auswertung ist nicht notwendig. |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.08 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |