Article image KA1322

Rechner Sensors KA1322

KAS-70-P50-A-G1/2-LCP-Z02-1-HP

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Smart Paddle. Capacitive. Overfill. Leakage Control. For Containers that contain water-polluting liquids, the Water Resources Act (in Germany WHG) prescribes overfill protection. Also the leak detection sensors, which are placed in the drip trays serve as a, water protection device in accordance with the water protection Act (WHG).

Downloads

Technical parameters

Thread / Process connection: G 1/2"
Housing material active surface: LCP
Housing material: LCP
Housing material lid: PA
Electrical version: 4-Leiter DC
Operating current (Ie): 2 x 0…250 mA
Voltage drop max. (Ud): ≤ 2 V
Permitted residual ripple max.: 10%
Noload current (Io): Typ. 15 mA
Frequency of operating cycles max.: 2 Hz
LEDdisplay: Grün / Gelb
Protective circuit: Eingebaut
Degree of protection IEC 60529: IP 67 (mit versiegelter Potentiometerschraube)
Norm: EN 60947-5-2
Sensitivity: Er 2…80
Pressure: 10 bar
Media optimized: JA
Quattro Protect: JA
Sensing dinstance Sn: produktberuehrend-mediumabhaengig-einstellbar
Operating voltage: 10…35 V DC
Permitted ambient temperature min.: -25 °C
Permitted ambient temperature max.: +70 °C
Installation: Nichtbündig
Output function: Antivalent (S + Ö)
Output signal: NPN
Cable length: 2 m
Connection: PVC-Kabel, 4 x 0,34 mm²
CE: JA
RoHS: JA
UL CSA certification: JA
MTTF: 529,1 Jahre
WHG certification: Auf Anfrage

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m