IA0063
IAS-30-A23-N, ATEX, 10 m
Inductive Sensors. Series 30 – NAMUR EN 60947-5-6. Housing M 18 x 1. Housing material: Brass. For use in areas with the risk of gas explosion, zone 0. Sensing distance Sn = 8 mm. DMT 03 ATEX E 048 IECEx BVS 07.0031. II 1G Ex ia IIC T1-T6 Ga Ex ia IIC T1-T6 Ga. CNEX
Thread / Process connection: | M 18 x 1 |
Housing material active surface: | PPO |
Housing material: | Messing |
Housing material lid: | PA |
Electrical version: | 2-Leiter DC |
Permitted residual ripple max.: | 5% |
Protective circuit: | Eingebaut |
Degree of protection IEC 60529: | IP 67 |
Norm: | EN 60947-5-6 |
Selfinductance (L): | 2 mH |
Selfcapacitance (C): | 250 nF |
Operating current active surface free: | > typ. 2 mA |
Operating current active surface covered: | < typ. 1,5 mA |
Sensing dinstance Sn: | 8 mm |
Operating voltage: | 5…15 V DC, Ui = 15 V DC |
Permitted ambient temperature min.: | -20 °C |
Permitted ambient temperature max.: | +70 °C |
Installation: | Nichtbündig |
Output function: | NAMUR |
Cable length: | 10 m |
Connection: | PVC-Kabel, 2 x 0,34 mm² |
CE: | JA |
RoHS: | JA |
ATEX product marking gas: | Ex II 1G Ex ia Ex IIC T1 – T6 Ga |
Certified Zones ATEX: | 1G |
IECEX product marking gas: | Ex ia IIC T1 – T6 Ga |
MTTF: | 3664,46 Jahre |
WHG certification: | Auf Anfrage |
ECCN: | |
Country of Origin: | |
EAN: | |
Weight: | 0.00 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |