Article image UB20.241

Puls UB20.241

DC-UPS control unit

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

No change in output voltage in battery mode, selectable output voltages in battery mode. 1-Battery-Concept each 12V battery is charged and, monitored separately for longest battery life. Precise battery charging by using a temperature sensor. Battery size selector for small or large batteries. 50% BonusPower®, 30A for up to 4s. High breaking capacity for branch protectors. Smart battery diagnostics and monitoring functions

Technical parameters

DC-Input Voltage: DC 24V
Int. Current consumption (incl. Charging Current): 1,8/3,5A
Nominal Voltage: 24Vdc
Output Current: 25A
Output Power: 600W
Storage element: external lead acid battery
Allowed Battery Size: 24V, 3.9 to 40Ah
Temperature Tracking of the End-of-Charge Voltage: automatically with temp. Sensor
Size (WxHxD): 46mm x 124mm x 127mm
Weight per Piece (excluding packing): 700g
Operat. Temperature Range: -40°C ... +70°C
Derating: 0,5W/°C at >+60°C
Mounting Method: Din-Rail
MTBF SN 29500 @ 40°C (h): 649.000h
Connection method: screw terminals
I2): 15A/360W resp. 30A/720W for up to 5s

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m