Phoenix Contact 3002371

PTU 35/4X10

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Note: In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered.
Number of levels: 1
Number of connections: 5
Nominal cross section: 16 mm²
Color: gray
Insulating material: PA
Flammability rating according to UL 94: V0
Rated surge voltage: 8 kV
Degree of pollution: 2
Overvoltage category: III
Insulating material group: I
Maximum power dissipation for nominal condition: 4.06 W (the value is multiplied when connecting multiple levels)
Ambient temperature (operation): -60 °C ... 85 °C
Ambient temperature (storage/transport): -25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C)
Permissible humidity (storage/transport): 30 % ... 70 %
Ambient temperature (assembly): -5 °C ... 70 °C
Ambient temperature (actuation): -5 °C ... 70 °C
Connection method: Screw connection
Connection in acc. with standard: IEC 60947-7-1
Maximum load current: 101 A (The maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal current IN: 101 A
Nominal voltage UN: 1000 V
Connection method: Push-in connection
Connection in acc. with standard: IEC 60947-7-1
Maximum load current: 57 A
Nominal current IN: 57 A
Nominal voltage UN: 1000 V
Open side panel: No
Back of the hand protection: guaranteed
Finger protection: guaranteed
Result of surge voltage test: Test passed
Surge voltage test setpoint: 9.8 kV
Result of power-frequency withstand voltage test: Test passed
Power frequency withstand voltage setpoint: 2.2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection): Test passed
Result of bending test: Test passed
Bending test rotation speed: 10 rpm
Bending test turns: 135
Bending test conductor cross section/weight: 2.5 mm² / 0.7 kg
Tensile test result: Test passed
Conductor cross section tensile test: 2.5 mm²
Tractive force setpoint: 50 N
Conductor cross section tensile test: 10 mm²
Tractive force setpoint: 90 N
Conductor cross section tensile test: 35 mm²
Tractive force setpoint: 190 N
Result of tight fit on support: Test passed
Tight fit on carrier: NS 35
Setpoint: 5 N
Result of voltage-drop test: Test passed
Requirements, voltage drop: ≤ 1.6 mV
Result of temperature-rise test: Test passed
Short circuit stability result: Test passed
Conductor cross section short circuit testing: 10 mm²
Short-time current: 1.2 kA
Conductor cross section short circuit testing: 16 mm²
Short-time current: 1.92 kA
Conductor cross section short circuit testing: 35 mm²
Short-time current: 4.2 kA
Result of aging test: Test passed
Ageing test for screwless modular terminal block temperature cycles: 192
Result of thermal test: Test passed
Proof of thermal characteristics (needle flame) effective duration: 30 s
Oscillation, broadband noise test result: Test passed
Test specification, oscillation, broadband noise: DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum: Service life test category 2, bogie-mounted
Test frequency: f1 = 5 Hz to f2 = 250 Hz
ASD level: 6.12 (m/s2)2/Hz
Acceleration: 3.12 g
Test duration per axis: 5 h
Test directions: X-, Y- and Z-axis
Shock test result: Test passed
Test specification, shock test: DIN EN 50155 (VDE 0115-200):2008-03
Shock form: Half-sine
Acceleration: 30g
Shock duration: 18 ms
Number of shocks per direction: 3
Test directions: X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B): 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130 °C
Static insulating material application in cold: -60 °C
Surface flammability NFPA 130 (ASTM E 162): passed
Specific optical density of smoke NFPA 130 (ASTM E 662): passed
Smoke gas toxicity NFPA 130 (SMP 800C): passed
Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
Width: 19.4 mm
Length: 79.9 mm
Height NS 35/7,5: 50.3 mm
Height NS 35/15: 57.8 mm
Connection method: Screw connection
Connection in acc. with standard: IEC 60947-7-1
Screw thread: M6
Tightening torque, min: 3.2 Nm
Tightening torque max: 3.7 Nm
Stripping length: 18 mm
Conductor cross section solid min.: 1.5 mm²
Conductor cross section solid max.: 50 mm²
Conductor cross section AWG min.: 8
Conductor cross section AWG max.: 2
Conductor cross section flexible min.: 1.5 mm²
Conductor cross section flexible max.: 35 mm²
Min. AWG conductor cross section, flexible: 8
Max. AWG conductor cross section, flexible: 2
Conductor cross section flexible, with ferrule without plastic sleeve min.: 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.: 35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.: 1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.: 35 mm²
2 conductors with same cross section, solid min.: 1.5 mm²
2 conductors with same cross section, solid max.: 16 mm²
Two conductors with the same cross section, AWG solid min.: 16
Two conductors with the same cross section, AWG solid max.: 6
2 conductors with same cross section, stranded min.: 1.5 mm²
2 conductors with same cross section, stranded max.: 10 mm²
Two conductors with the same cross section, AWG stranded, min.: 16
Two conductors with the same cross section, AWG stranded, max.: 8
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum: 1.5 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum: 10 mm²
Connection cross sections directly pluggable: 1 mm² 16 mm² 16 6 4 mm² 10 mm²
Conductor cross section solid min.: 1 mm²
Conductor cross section solid max.: 16 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 6
Conductor cross section flexible min.: 4 mm²
Conductor cross section flexible max.: 10 mm²
Internal cylindrical gage: B9
Connection method: Push-in connection
Connection in acc. with standard: IEC 60947-7-1
Conductor cross section solid min.: 0.5 mm²
Conductor cross section solid max.: 16 mm²
Conductor cross section AWG min.: 20
Conductor cross section AWG max.: 6
Conductor cross section flexible min.: 0.5 mm²
Conductor cross section flexible max.: 10 mm²
Min. AWG conductor cross section, flexible: 20
Max. AWG conductor cross section, flexible: 8
Conductor cross section flexible, with ferrule without plastic sleeve min.: 0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.: 10 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.: 0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.: 10 mm²
Connection in acc. with standard: IEC 60947-7-1
Flammability rating according to UL 94: V0
eCl@ss 10.0.1: 27141120
eCl@ss 4.0: 27141127
eCl@ss 4.1: 27141127
eCl@ss 5.0: 27141127
eCl@ss 5.1: 27141111
eCl@ss 6.0: 27141100
eCl@ss 7.0: 27141120
eCl@ss 8.0: 27141120
eCl@ss 9.0: 27141120
ETIM 3.0: EC000897
ETIM 4.0: EC000897
ETIM 5.0: EC000897
ETIM 6.0: EC000897
ETIM 7.0: EC000897
UNSPSC 6.01: 30211812
UNSPSC 7.0901: 39121410
UNSPSC 11: 39121411
UNSPSC 12.01: 39121411
UNSPSC 13.2: 39121411
UNSPSC 18.0: 39121410
UNSPSC 19.0: 39121410
UNSPSC 20.0: 39121410
UNSPSC 21.0: 39121410

Logistic parameters

ECCN:
Country of Origin: IN
EAN:
Weight: 0.071 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m