Width: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Degree of protection: IP20
Ambient temperature (operation): -25 °C ... 55 °C up to 2000 m above mean sea level
Ambient temperature (storage/transport): -25 °C ... 85 °C
Permissible humidity (operation): 30 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport): 5 % ... 95 %
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Shock: 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Supports cloud computing: yes
Cloud platform: Proficloud
Weight: 144.5 g
Note on weight specifications: with connectors
Interface: RS-232
Connection method: COMBICON connectors
Interface: RS-485
Number: 1
Connection method: COMBICON connectors
Interface: Ethernet
Number: 2
Connection method: RJ45
Transmission speed: 100 Mbps
Protocols supported: Modbus/RTU (Master)
Interface: Service
Number: 1
Connection method: USB type C
Typical current consumption: 200 mA
Supply voltage: 24 V DC -20 % / +15 %
Supply voltage range: 18 V DC ... 30 V DC
Processor: Arm® Cortex®-A8 1x 600 MHz
Realtime clock: Yes
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Interference emission: Noise emission test according to EN 61000-6-3 Class B
Immunity to surge: Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity to burst: Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to EF: Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESD: Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity to conducted interference: Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Shock: 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Shock (operation): 10g (Bump endurance test according to DIN EN 60068-2-27)
China RoHS: Environmentally friendly use period: unlimited = EFUP-e
eCl@ss 10.0.1: 27242608
eCl@ss 5.1: 27242608
eCl@ss 6.0: 27242600
eCl@ss 7.0: 27242608
eCl@ss 8.0: 27242608
eCl@ss 9.0: 27242608
ETIM 3.0: EC001604
ETIM 4.0: EC001604
ETIM 5.0: EC001604
ETIM 6.0: EC001604
ETIM 7.0: EC001604

Logistic parameters

ECCN:
Country of Origin: DE
EAN: