192144
SB4 Module 4X
Accessories Safety. Safety control unit module
Empty housing for Evaluation unit SB4fa. OSSD-R/Supply-module, Safety outputs OSSD, external status displays OSSD, Start/Restart disable , Operating mode can be selected by means of DIP switches, Relay monitor, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa. OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC ± 20 % ,. 24 V DC ± 20 % , via SB4 Housingfa, cover sheetfa. Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa. Sensor module, 4 sensor channels, Operating mode can be selected by means of DIP switches, Individual module for SLA5(S), SLA20, SLA25, SLA28 and SLA40 security through-beam sensors; for SLP safety light grids, for SLC safety light curtains; for switching pads and emergency stop buttons of categories 2 or 4, Screw terminals or spring terminals, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa. Muting module, 4 sensor channels, Double muting, Continuous muting with no time limit, Emergency muting for the correction of the material jam, Operating voltage: 24 V DC ± 20 % ,. Muting module, 4 sensor channels, Double muting, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Operating voltage: 24 V DC ± 20 % ,. Sensor module, 4 sensor channels, Micro-Controller controls, Operating mode can be selected by means of DIP switches, Individual module for SLA5(S), SLA20, SLA25, SLA28 and SLA40 security through-beam sensors; for SLP safety light grids, for SLC safety light curtains; for switching pads and emergency stop buttons of categories 2 or 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa. Sensor module, 6 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa. Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa. Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa
ECCN: | |
Country of Origin: | Deutschland |
EAN: | 4050143020096 |
Weight: | 0.13 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |