Article image 50132993

Leuze electronic 50132993

MSI-EM-I8-03

MSI-EM-I8-03 - Safe input module

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Series: MSI-EM
Application: Monitoring of safety functions
Number of safe I/Os: 8 IN
Functions: Extension module for the MSI 400 configurable safety control, Extension with 8 safe inputs
SIL: 3, IEC 61508
SILCL: 3, IEC/EN 62061
Performance Level (PL): e, EN ISO 13849-1
PFHD: 5,68E-09 per hour
Mission time: 20 years, EN ISO 13849-1
Category: 4, EN ISO 13849
Power consumption, max.: 1.4 W
Number of inputs: 8 Piece(s)
Voltage permitted at the input: 30 V
Input current at signal 1: 8 mA
Type: Internal bus (SBUS+)
Number of connections: 1 Piece(s)
Function: Signal IN
Type of connection: Terminal
Type of terminal: Spring-cage terminal
No. of pins: 16 -pin
Connection cross sections: 2 x 0.2 to 1.5 mm², wire, 2 x 0.2 to 1.5 mm², wire, 2 x 0.25 to 1.5 mm², wire with wire-end sleeve (pressed in trapezium shape)
Dimension (W x H x L): 22.5 mm x 107 mm x 120.8 mm
Net weight: 150 g
Housing color: Gray
Type of fastening: Snap-on mounting
Ambient temperature, operation: -25 ... 65 °C
Ambient temperature, storage: -25 ... 70 °C
Relative humidity (non-condensing): 10 ... 95 %
Degree of protection: IP 20 (terminals), IP 40 (housing)
Protection class: III
Certifications: c UL US, TÜV Rheinland
Vibration resistance: 5 ... 500 Hz
Test procedure for oscillation in accordance with standard: EN 60068-2-6
Shock resistance, continuous shock: 10 g, 16 ms, EN 60068-2-29
Shock resistance, single shock: 30 g, 11 ms, EN 60068-2-27
Customs tariff number: 85364900
eCl@ss 8.0: 27242204
eCl@ss 9.0: 27242204
ETIM 5.0: EC001419
ETIM 6.0: EC001419

Logistic parameters

ECCN:
Country of Origin: Deutschland
EAN:
Weight: 0.21 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m