SD9500
Compressed air meter. SDR32DGXFRKG/US-100
Precise measurement of flow, consumption, pressure and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. Red/green display for clear identification of the acceptable range. Display can be rotated for optimum alignment
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection R 1 1/2 DN40 |
Measuring range: | -10...60 °C 14...140 °F |
-10...60 °C: | 14...140 °F |
Application: | for industrial applications |
Media: | compressed air |
Medium temperature [°C]: | -10...60 |
Min. bursting pressure [bar]: | 64 |
Min. bursting pressure [MPa]: | 6.4 |
Pressure rating [bar]: | 16 |
Pressure rating [Mpa]: | 1.6 |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 80 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 1 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs: | counter reset |
Output signal: | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 150; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Pulse output: | consumed quantity meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 20...6830 l/min 0.3...81 m/s 1.4...410 m³/h |
20...6830 l/min: | 0.3...81 m/s |
Display range: | 0...8200 l/min 0...97.2 m/s 0...492 m³/h |
0...8200 l/min: | 0...97.2 m/s |
Resolution: | 10 l/min 0.1 m/s 0.2 m³/h |
10 l/min: | 0.1 m/s |
Set point SP: | 60...6830 l/min 0.7...81 m/s 3.6...409.8 m³/h |
60...6830 l/min: | 0.7...81 m/s |
Reset point rP: | 30...6800 l/min 0.3...80.6 m/s 1.6...407.8 m³/h |
30...6800 l/min: | 0.3...80.6 m/s |
Analogue start point ASP: | 0...5460 l/min 0...64.8 m/s 0...327.9 m³/h |
0...5460 l/min: | 0...64.8 m/s |
Analogue end point AEP: | 1370...6830 l/min 16.2...81 m/s 82.1...410 m³/h |
1370...6830 l/min: | 16.2...81 m/s |
Low flow cut-off LFC: | 10...70 l/min 0.1...0.9 m/s 0.5...4.4 m³/h |
10...70 l/min: | 0.1...0.9 m/s |
In steps of: | 1 l/min 0.1 m/s 0.1 m³/h |
1 l/min: | 0.1 m/s |
Measuring range [bar]: | -1...16 |
Display range [bar]: | -1...20 |
Resolution [bar]: | 0.05 |
Set point SP [bar]: | -0.92...16 |
Reset point rP [bar]: | -1...15.92 |
Analogue start point [bar]: | -1...12.8 |
Analogue end point [bar]: | 2.2...16 |
In steps of [bar]: | 0.01 |
Measuring range: | 0...100000000 m³ 0...353146667.2 scf |
0...100000000 m³: | 0...353146667.2 scf |
Display range: | 0...100000000 m³ 0...353146667.2 scf |
0...100000000 m³: | 0...353146667.2 scf |
Set point SP: | 0.001...10000000 m³ 0.05...353146667.2 scf |
0.001...10000000 m³: | 0.05...353146667.2 scf |
Pulse value: | 0.001...10000000 m³ 0.05...353146667.2 scf |
0.001...10000000 m³: | 0.05...353146667.2 scf |
In steps of: | 0.0001 m³ 0.005 scf |
0.0001 m³: | 0.005 scf |
Pulse length [s]: | 0.004...2 |
Measuring range: | -10...60 °C 14...140 °F |
-10...60 °C: | 14...140 °F |
Display range: | -24...74 °C -11.2...165.2 °F |
-24...74 °C: | -11.2...165.2 °F |
Resolution: | 0.2 °C 0.5 °F |
0.2 °C: | 0.5 °F |
Set point SP: | -9.7...60 °C 14.6...140 °F |
-9.7...60 °C: | 14.6...140 °F |
Reset point rP: | -10...59.7 °C 14...139.4 °F |
-10...59.7 °C: | 14...139.4 °F |
Analogue start point: | -10...46 °C 14...114.8 °F |
-10...46 °C: | 14...114.8 °F |
Analogue end point: | 4...60 °C 39.2...140 °F |
4...60 °C: | 39.2...140 °F |
In steps of: | 0.1 °C 0.1 °F |
0.1 °C: | 0.1 °F |
Temperature coefficient [1/K]: | ± 0,07 % MW |
Accuracy (in the measuring range): | class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C |
Repeatability: | ± (0,4 % MW + 0,1 % MEW) |
Repeatability [% of the final value]: | ± 0,2 |
Characteristics deviation [% of the final value]: | < ± 0,5; (BFSL = Best Fit Straight Line) |
Greatest TEMPCO of the span [% MEW / 10 K]: | ± 0,15 |
Greatest TEMPCO of the zero point [% MEW / 10 K]: | ± 0,25 |
Accuracy [K]: | ± 0,5; (medium flow in the limit area of the flow measurement range) |
Response time [s]: | 0.1; (dAP = 0) |
Damping for the switching output dAP [s]: | 0...5 |
Response time [s]: | 0.05 |
Dynamic response T05 / T09 [s]: | T09 = 0,5 |
Parameter setting options: | hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 CDV |
IO-Link device ID: | 869 d / 00 03 65 h |
Profiles: | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 8 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 7.2 |
Ambient temperature [°C]: | 0...60 |
Storage temperature [°C]: | -20...85 |
Max. relative air humidity [%]: | 90 |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 60947-5-9 |
Vibration resistance: | DIN EN 68000-2-6 5 g (10...2000 Hz) |
DIN EN 68000-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 183 |
UL approval: | UL Approval no. I012 File number UL E174189 |
UL Approval no.: | I012 |
File number UL: | E174189 |
Pressure Equipment Directive: | Sound engineering practice; can be used for stable gases fluid group 2 |
Weight [K40]: | 2262 |
Materials: | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
Materials (wetted parts): | stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
Process connection: | threaded connection R 1 1/2 DN40 |
Display: | colour display 1,44", 128 x 128 pixels 2 x LED, yellow |
Remarks: | MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. For information about installation and operation please see the operating instructions. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 2.26 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |