Ifm SD8501

Compressed air meter. SDN11DGXFRKG/US-100

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption, pressure and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. Red/green display for clear identification of the acceptable range. Display can be rotated for optimum alignment

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection 1" NPT DN25
Measuring range: -10...60 °C 14...140 °F
-10...60 °C: 14...140 °F
Application: for industrial applications
Media: compressed air
Medium temperature [°C]: -10...60
Min. bursting pressure [psi]: 928
Pressure rating [psi]: 232
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 80
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Inputs: counter reset
Output signal: switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 150; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 25...7945 scfh 0.4...132.4 scfm 1.2...340.2 ft/s
25...7945 scfh: 0.4...132.4 scfm
Display range: 0...9535 scfh 0...158.9 scfm 0...408.2 ft/s
0...9535 scfh: 0...158.9 scfm
Resolution: 5 scfh 0.1 scfm 0.2 ft/s
5 scfh: 0.1 scfm
Set point SP: 69...7943 scfh 1.1...132.4 scfm 3...340.1 ft/s
69...7943 scfh: 1.1...132.4 scfm
Reset point rP: 30...7904 scfh 0.5...131.7 scfm 1.3...338.4 ft/s
30...7904 scfh: 0.5...131.7 scfm
Analogue start point ASP: 0...6357 scfh 0...105.9 scfm 0...272.2 ft/s
0...6357 scfh: 0...105.9 scfm
Analogue end point AEP: 1589...7946 scfh 26.5...132.4 scfm 68...340.2 ft/s
1589...7946 scfh: 26.5...132.4 scfm
Low flow cut-off LFC: 9...85 scfh 0.2...1.4 scfm 0.4...3.6 ft/s
9...85 scfh: 0.2...1.4 scfm
In steps of: 1 scfh 0.1 scfm 0.1 ft/s
1 scfh: 0.1 scfm
Measuring range [psi]: -15...232
Display range [psi]: -15...290
Resolution [psi]: 1
Set point SP [psi]: -13...232
Reset point rP [psi]: -15...231
Analogue start point [psi]: -15...186
Analogue end point [psi]: 32...232
In steps of [psi]: 1
Measuring range: 0...100000000 m³ 0...353146667.2 scf
0...100000000 m³: 0...353146667.2 scf
Display range: 0...100000000 m³ 0...353146667.2 scf
0...100000000 m³: 0...353146667.2 scf
Set point SP: 0.001...10000000 m³ 0.05...353146667.2 scf
0.001...10000000 m³: 0.05...353146667.2 scf
Pulse value: 0.001...10000000 m³ 0.05...353146667.2 scf
0.001...10000000 m³: 0.05...353146667.2 scf
In steps of: 0.0001 m³ 0.005 scf
0.0001 m³: 0.005 scf
Pulse length [s]: 0.007...2
Measuring range: -10...60 °C 14...140 °F
-10...60 °C: 14...140 °F
Display range: -24...74 °C -11.2...165.2 °F
-24...74 °C: -11.2...165.2 °F
Resolution: 0.2 °C 0.5 °F
0.2 °C: 0.5 °F
Set point SP: -9.7...60 °C 14.6...140 °F
-9.7...60 °C: 14.6...140 °F
Reset point rP: -10...59.7 °C 14...139.4 °F
-10...59.7 °C: 14...139.4 °F
Analogue start point: -10...46 °C 14...114.8 °F
-10...46 °C: 14...114.8 °F
Analogue end point: 4...60 °C 39.2...140 °F
4...60 °C: 39.2...140 °F
In steps of: 0.1 °C 0.1 °F
0.1 °C: 0.1 °F
Temperature coefficient [1/K]: ± 0,07 % MW
Accuracy (in the measuring range): class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 73 °F
Repeatability: ± (0,4 % MW + 0,1 % MEW)
Repeatability [% of the final value]: ± 0,2
Characteristics deviation [% of the final value]: < ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K]: ± 0,15
Greatest TEMPCO of the zero point [% MEW / 10 K]: ± 0,25
Accuracy [K]: ± 0,5; (medium flow in the limit area of the flow measurement range)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP [s]: 0...5
Response time [s]: 0.05
Dynamic response T05 / T09 [s]: T09 = 0,5
Parameter setting options: hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 867 d / 00 03 63 h
Profiles: Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO mode: yes
Required master port type: A
Process data analogue: 8
Process data binary: 2
Min. process cycle time [ms]: 7.2
Ambient temperature [°F]: 32...140
Storage temperature [°C]: -4...185
Max. relative air humidity [%]: 90
Protection: IP 65; IP 67
EMC: DIN EN 60947-5-9
Vibration resistance: DIN EN 68000-2-6 5 g (10...2000 Hz)
DIN EN 68000-2-6: 5 g (10...2000 Hz)
MTTF [years]: 183
UL approval: UL Approval no. I012 File number UL E174189
UL Approval no.: I012
File number UL: E174189
Pressure Equipment Directive: Sound engineering practice; can be used for stable gases fluid group 2
Weight [K40]: 1581
Materials: PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts): stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connection: threaded connection 1" NPT DN25
Display: colour display 1,44", 128 x 128 pixels 2 x LED, yellow
Remarks: MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. For information about installation and operation please see the operating instructions.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 1.61 kg
Length: 0.00 m
Width: 0.00 m