Ifm SB1234

Flow meter with integrated backflow prevention and display. SBG34KL0FRKG

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Process connection: threaded connection G 3/4 internal thread
Measuring range: -10...100 °C 14...212 °F
-10...100 °C: 14...212 °F
Special feature: Gold-plated contacts
Media: Liquids; oil
Note on media: oil with viscosity: 10 mm²/s (40 °C)
Medium temperature [°C]: -10...100
Pressure rating [bar]: 100
Note on pressure rating: at medium temperature >70°C: 80
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 50
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: < 3
Total number of outputs: 2
Output signal: switching signal; analogue signal; frequency signal; IO-Link
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Max. current load per output [mA]: 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature)
Analogue current output [mA]: 4...20
Max. load [Ω]: 500
Short-circuit protection: yes
Overload protection: yes
Frequency of the output [Hz]: 0...10000
Measuring range: 1...50 l/min 0.06...3 m³/h 16...793 gph 0.26...13.2 gpm
1...50 l/min: 0.06...3 m³/h
Display range: 0...60 l/min 0...3.6 m³/h 0...951 gph 0...15.86 gpm
0...60 l/min: 0...3.6 m³/h
Resolution: 0.01 l/min 0.001 m³/h 1 gph 0.01 gpm
0.01 l/min: 0.001 m³/h
Set point SP: 0.35...50 l/min 0.02...3 m³/h 5...793 gph 0.08...13.2 gpm
0.35...50 l/min: 0.02...3 m³/h
Reset point rP: 0...49.65 l/min 0...2.98 m³/h 0...787 gph 0...13.12 gpm
0...49.65 l/min: 0...2.98 m³/h
Frequency end point, FEP: 3.35...50 l/min 0.2...3 m³/h 53...793 gph 0.88...13.2 gpm
3.35...50 l/min: 0.2...3 m³/h
In steps of: 0.05 l/min 0.005 m³/h 1 gph 0.02 gpm
0.05 l/min: 0.005 m³/h
Frequency at the end point FRP [Hz]: 10...10000
In steps of [Hz]: 10
Measuring dynamics: 1:50
In steps of: 10 Hz
Measuring range: -10...100 °C 14...212 °F
-10...100 °C: 14...212 °F
Display range: -32...122 °C -25.6...251.6 °F
-32...122 °C: -25.6...251.6 °F
Resolution: 0.1 °C 0.1 °F
0.1 °C: 0.1 °F
Set point SP: -9.3...100 °C 15.2...212 °F
-9.3...100 °C: 15.2...212 °F
Reset point rP: -10...99.3 °C 14...210.8 °F
-10...99.3 °C: 14...210.8 °F
In steps of: 0.1 °C 0.2 °F
0.1 °C: 0.2 °F
Frequency start point, FSP: -10...78 °C 14...172.4 °F
-10...78 °C: 14...172.4 °F
Frequency end point, FEP: 12...100 °C 53.6...212 °F
12...100 °C: 53.6...212 °F
Frequency at the end point FRP [Hz]: 10...10000
Accuracy (in the measuring range): ± 5 % MEW; (Q > 1 l/min; 20...70 °C Medium temperature)
Repeatability: ± 1 % MEW
Temperature drift: 0,029 °C / K
Accuracy [K]: 3 K (25°C; Q > 1 l/min)
Response time [s]: 0.01
Damping for the switching output dAP [s]: 0...5
In steps of [s]: 0.1
Damping for the analogue output dAA [s]: 0...5
In steps of [s]: 0.1
Dynamic response T05 / T09 [s]: T09 = 120 (Q > 1 l/min)
Parameter setting options: hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 1045 d / 0415 h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 2
Process data binary: 2
Min. process cycle time [ms]: 3.2
Ambient temperature [°C]: 0...60
Note on ambient temperature: medium temperature < 80 °C medium temperature < 100 °C: 0...40 °C
Storage temperature [°C]: -15...80
Protection: IP 65; IP 67
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 60068-2-27 20 g (11 ms)
DIN EN 60068-2-27: 20 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 145
UL approval: UL Approval no. I005
UL Approval no.: I005
Pressure Equipment Directive: Sound engineering practice
Weight [g]: 989
Materials: stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts): stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Process connection: threaded connection G 3/4 internal thread
Switching cycles mechanical: 10 million
Display: Display unit 6 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, red/green alternating indication 4-digit programming alphanumeric display, 4-digit
Display unit: 6 x LED, green
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green alternating indication 4-digit
programming: alphanumeric display, 4-digit
Remarks: Recommendation: use a 200-micron filter. All data refer to oil with the following nominal viscosity: 10 mm²/s, 40 °C MW = measured value MEW = Final value of the measuring range
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.99 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m