PX9118
Pressure transmitter with ceramic measuring cell. PA-010WRBN14-B-DVG/US/ /V
Robust design for use in mobile machines. Precise analogue output. With long-term stability thanks to high overload protection. Lifespan of more than 100 million pressure cycles. High shock and vibration resistance
Output signal: | analogue signal |
Measuring range [inH2O]: | 0...100 |
Process connection: | threaded connection 1/4" NPT external thread internal thread:M5 |
Special feature: | Gold-plated contacts |
Application: | for industrial applications |
Media: | liquids and gases |
Medium temperature [°C]: | -25...90 |
Min. bursting pressure [inH2O]: | 12043 |
Pressure rating [inH2O]: | 2400 |
Type of pressure: | relative pressure |
Operating voltage [V]: | 16...32 DC |
Current consumption [mA]: | < 18 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal |
Number of analogue outputs: | 1 |
Analogue voltage output [V]: | 0...10 |
Min. load resistance [Ω]: | 2000 |
Overload protection: | yes |
Measuring range [inH2O]: | 0...100 |
Repeatability [% of the span]: | < 0,15; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,35 (BFSL) / < ± 0,75 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,3; (0...80 °C) |
Step response time analogue output [ms]: | 3 |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 30 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V radiation of interference according to the automotive directive 2004/104/EC / CISPR 25 immunity according to the automotive directive 2004/104/EC / ISO 11452-2 HF radiated 100 V/m pulse resistance ISO 7637-2 / severity level 3 |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 30 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
radiation of interference: | according to the automotive directive 2004/104/EC / CISPR 25 |
immunity: | according to the automotive directive 2004/104/EC / ISO 11452-2 |
HF radiated: | 100 V/m |
pulse resistance: | ISO 7637-2 / severity level 3 |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 550 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 213 |
Materials: | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X |
Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection 1/4" NPT external thread internal thread:M5 |
Restrictor element integrated: | no (can be retrofitted) |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.21 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |