Technical parameters

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: 0...400 bar 0...5800 psi 0...40 MPa
0...400 bar: 0...5800 psi
Process connection: threaded connection G 1/4 internal thread
Special feature: Gold-plated contacts
Measuring element: ceramic-capacitive pressure measuring cell
Application: for industrial applications
Media: Liquids
Conditionally suitable for: use in gases at pressures > 25 bar only on request
Medium temperature [°C]: -25...80
Min. bursting pressure: 1200 bar 17400 psi 120 MPa
1200 bar: 17400 psi
Pressure rating: 600 bar 8700 psi 60 Mpa
600 bar: 8700 psi
Vacuum resistance [mbar]: -1000
Type of pressure: relative pressure
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 35
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.3
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: < 500
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable 1:5)
Max. load [Ω]: 500
Analogue voltage output [V]: 0...10; (scalable 1:5)
Min. load resistance [Ω]: 2000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 0...400 bar 0...5800 psi 0...40 MPa
0...400 bar: 0...5800 psi
Set point SP: 2.5...400 bar 40...5800 psi 0.25...40 MPa
2.5...400 bar: 40...5800 psi
Reset point rP: 1...398.5 bar 10...5780 psi 0.1...39.85 MPa
1...398.5 bar: 10...5780 psi
Analogue start point: 0...320 bar 0...4640 psi 0...32 MPa
0...320 bar: 0...4640 psi
Analogue end point: 80...400 bar 1160...5800 psi 8...40 MPa
80...400 bar: 1160...5800 psi
In steps of: 0.5 bar 10 psi 0.05 MPa
0.5 bar: 10 psi
Switch point accuracy [% of the span]: < ± 0,4; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,2; (-0...80 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,2; (-0...80 °C)
Response time [ms]: < 1.5
Delay time programmable dS, dr [s]: 0...50
Damping for the switching output dAP [s]: 0...4
Damping for the analogue output dAA [s]: 0...4
Max. response time analogue output [ms]: 3
Parameter setting options: hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 459 d / 00 01 cb h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 65; IP 67
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 161
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 0.001
Materials: stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts): stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Min. pressure cycles: 100 million
Tightening torque [Nm]: 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection: threaded connection G 1/4 internal thread
Restrictor element integrated: yes
Display: Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit
Display unit: 3 x LED, green (bar, psi, MPa)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m