Ifm LR7020

Continuous level sensor (guided wave radar). LR0000--BR34AQPKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

For the reliable level control in tanks and containers. Suitable for water, oils and coolants. Modular system consisting of evaluation unit and probe. Adaptation to different container heights through shortening of the probe

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2
Probe length L [mm]: 100...2000
Process connection: G 3/4 external thread
Special feature: Gold-plated contacts
Media: Liquids
Dielectric constant of the medium: ≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation)
Recommended media: water; hydrous media; oils; oil-based media
Medium temperature [°C]: -25...80; (90 < 1 h)
Tank pressure [bar]: -1...16
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 25
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: < 3
Number of inputs and outputs: Number of digital outputs: 2
Total number of outputs: 2
Output signal: switching signal; IO-Link
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 200
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Probe length L [mm]: 100...2000
Active range A [mm]: L-40; (when set to oil and oil based media: L-60)
Inactive range I1 / I2 [mm]: 30 / 10; (when set to oil and oil based media: 30 / 30)
Sampling rate [Hz]: 4
Set point SP [mm]: ≥ 15...L-30
Note on setpoint SP: when set to oil and oil based media: 35...L-30
Reset point rP [mm]: ≥ 10...L-35
Note on reset point rP: when set to oil and oil based media: 30...L-35
In steps of [mm]: 5
Hysteresis [mm]: > 5
Repeatability [mm]: ± 5
Measuring error [mm]: ± 7
Offset error [mm]: 5
Resolution [mm]: 1
Temperature drift per 10 K: ± 0.2 %
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 907 d / 00 03 8B h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 3.2
Ambient temperature [°C]: -25...60
Storage temperature [°C]: -40...85
Protection: IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3 : in a closed metal tank DIN EN 61000-6-4 : in plastic or open metal tanks
DIN EN 61000-6-3: : in a closed metal tank
DIN EN 61000-6-4: : in plastic or open metal tanks
Shock resistance: DIN EN 60068-2-27 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
DIN EN 60068-2-27: 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
DIN EN 60068-2-6: 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
MTTF [years]: 286
UL approval: UL Approval no. H010 File number UL E174191
UL Approval no.: H010
File number UL: E174191
Weight [g]: 484.4
Materials: stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI
Materials (wetted parts): stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre
Process connection: G 3/4 external thread
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.48 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m