Ifm KQ1000

Electronic level sensor. KQ-5xxxNFPKG/IO

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Continuously measuring level from outside. No stress caused by the medium thanks to non-contact detection. Three point level sensors in one unit. Deposits can be detected and signalled to improve quality of the process. Linking several KQ10 via IO-Link

Technical parameters

Electrical design: PNP/NPN; (parameterisable)
Communication interface: IO-Link
Dimensions [mm]: 250 x 28 x 16.7
Media: dry bulk material; aqueous solutions; oils
Cannot be used for: highly adhesive media
Operating voltage [V]: 10...30 DC; (IO-Link: 18...30 DC)
Current consumption [mA]: < 50
Protection class: III
Reverse polarity protection: yes
Max. power-on delay time [ms]: 1300
Number of inputs and outputs: Number of digital outputs: 3
Electrical design: PNP/NPN; (parameterisable)
Number of digital outputs: 3
Permanent current rating of switching output DC [mA]: 200
Max. resistance switching output [Ω]: 8
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range [mm]: < 200
Detection range [mm]: 228
Set point SP [%]: 5...95
Reset point rP [%]: 4...94
In steps of [%]: 1
Repeatability [% of the final value]: 2
Offset deviation [% of the final value]: 4
Resolution [% of the final value]: 1
Linearity deviation [% of the final value]: 1
Response time [ms]: 1300
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
Profiles: Digital Measuring Sensor Profile, Common Profile
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 3
Min. process cycle time [ms]: 9.6
IO-Link process data (cyclical): function bit length process value 16 exponent 8 device status 4 binary switching information 3
function: bit length
process value: 16
exponent: 8
device status: 4
binary switching information: 3
IO-Link functions (acyclical): direction of installation; limitation of sensor elements; sensitivity; minimum recognition threshold; Performance in case of a fault; error delay; Damping; LED_Modus; switch-on cycle counter; operating hours counter; switching cycles counter; min./max. process value; internal temperature; min./max. internal temperature; diagnostic data for level
Supported DeviceIDs: Type of operation IO-Link device ID Default 924 d / 00 03 9C h
Type of operation: IO-Link device ID
Default: 924 d / 00 03 9C h
Note: For further information please see the IODD PDF file under "Downloads"
Applications: DIN EN 60654-1 application class B2
Ambient temperature [°C]: -20...80
Storage temperature [°C]: -25...85
Protection: IP 65; IP 67
EMC: DIN EN 61000-6-4 30 - 230 MHz 40 dBµV/m QP / 10 m distance 230 - 1 GHz 47 dBµV/m QP / 10 m distance DIN EN 61000-4-2 ± 25 kV AD / ± 25 kV CD DIN EN 61000-4-3 80 MHz - / 1 GHz 10 V/m DIN EN 61000-4-4 ± 2.5 kV / 5 kHz ± 2.5 kV / 100 kHz DIN EN 61000-4-6 10 V
DIN EN 61000-6-4 30 - 230 MHz: 40 dBµV/m QP / 10 m distance
230 - 1 GHz: 47 dBµV/m QP / 10 m distance
DIN EN 61000-4-2: ± 25 kV AD / ± 25 kV CD
DIN EN 61000-4-3: 80 MHz - / 1 GHz 10 V/m
DIN EN 61000-4-4: ± 2.5 kV / 5 kHz
DIN EN 61000-4-6: 10 V
Shock resistance: EN 60068-2-27 15 g / 11 ms
EN 60068-2-27: 15 g / 11 ms
Vibration resistance: EN 60068-2-6 5 g (10...2000 Hz)
EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 290.43
UL approval: Ta -25...60 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL Approval no. D005 File number UL E174191
Ta: -25...60 °C
Enclosure type: Type 1
voltage supply: Limited Voltage/Current
UL Approval no.: D005
File number UL: E174191
Weight [g]: 432
Dimensions [mm]: 250 x 28 x 16.7
Materials: PBT; PC;
Display: operation 1 x LED, green switching status 3 x LED, yellow function 20 x LED, green
operation: 1 x LED, green
switching status: 3 x LED, yellow
function: 20 x LED, green
Accessories (supplied): adhesive tape: 1 x 1,2 x 23 x 240 mm
Accessories (optional): Mounting adapter:, E12675 Mounting adapter:, E12676 Fixing strap:, E10880
Remarks: when used on IO-Link class B masters switching outputs OUT2, OUT3 have to be switched off
Pack quantity: 1 pcs.
Connection: Cable: 2 m, PUR; 5 x 0.34 mm²

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.43 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m