Ifm IQ2011

Inductive sensor. IQ23008BAPKG/K1/2M/PUR

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Correction factor 1: Constant sensing range on all metals. Very high switching frequency. Long sensing range for high uptime. Particularly space-saving design. Wide operating temperature range

Technical parameters

Electrical design: PNP
Output function: normally closed
Sensing range [mm]: 8
Housing: rectangular
Dimensions [mm]: 20 x 8 x 32
Special feature: Drag chain suitability; Increased sensing range
Operating voltage [V]: 10...30 DC
Current consumption [mA]: < 20
Protection class: III
Reverse polarity protection: yes
Electrical design: PNP
Output function: normally closed
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 100
Switching frequency DC [Hz]: 2000
Short-circuit protection: yes
Overload protection: yes
Sensing range [mm]: 8
Real sensing range Sr [mm]: 8 ± 10 %
Operating distance [mm]: 0...6.48
Increased sensing range: yes
Correction factor: steel: 1 / stainless steel: 1 / brass: 1 / aluminium: 1 / copper: 1
Hysteresis [% of Sr]: 3...15
Switch point drift [% of Sr]: -10...10
Ambient temperature [°C]: -40...85
Protection: IP 65; IP 66; IP 67; IP 68
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
EN 55011: class B
Vibration resistance: EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
EN 60068-2-6 Fc: 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance: EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
EN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance: EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
EN 60068-2-27: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature change: EN 60068-2-14 Na TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles
EN 60068-2-14 Na: TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles
MTTF [years]: 1084
UL approval: Ta -40...60 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL Approval no. A021 File number UL E174191
Ta: -40...60 °C
Enclosure type: Type 1
voltage supply: Limited Voltage/Current
UL Approval no.: A021
File number UL: E174191
Weight [K40]: 78.6
Housing: rectangular
Mounting: flush mountable
Dimensions [mm]: 20 x 8 x 32
Materials: diecast zinc special coating; sensing face: LCP natural; LED window: TPU; potting: PUR
Drag chain suitability: yes
Drag chain suitability: bending radius for flexible use min. 10 x cable diameter bending cycles > 5 Mio.
bending radius for flexible use: min. 10 x cable diameter
bending cycles: > 5 Mio.
Display: Display operation 1 x LED, green switching status 1 x LED, yellow
Display operation: 1 x LED, green
switching status: 1 x LED, yellow
Pack quantity: 1 pcs.
Connection: Cable: 2 m, PUR, Ø 4.9 mm; 3 x 0.34 mm²

Logistic parameters

ECCN:
Country of Origin: RO
EAN:
Weight: 0.08 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m