IES223
Inductive sensor. IEB2003BARKG/V4A/AS
Suitable for industrial, mobile, cooling and lubricating applications. High protection rating for the requirements of harsh industrial environments. Flexible use thanks to large operating temperature range. Safe detection due to large sensing range and low sensor tolerances. Reduced storage due to wide range of applications
Electrical design: | PNP/NPN |
Output function: | normally open |
Sensing range [mm]: | 3 |
Housing: | threaded type |
Dimensions [mm]: | M8 x 1 / L = 30 |
Special feature: | Gold-plated contacts; Increased sensing range |
Application: | Industrial applications / factory automation |
Operating voltage [V]: | 10...30 DC |
Current consumption [mA]: | < 20 |
Protection class: | III |
Reverse polarity protection: | yes |
Electrical design: | PNP/NPN |
Output function: | normally open |
Max. voltage drop switching output DC [V]: | 2.5 |
Max. leakage current [mA]: | 0.5 |
Permanent current rating of switching output DC [mA]: | 100 |
Switching frequency DC [Hz]: | 800 |
Short-circuit protection: | yes |
Overload protection: | yes |
Sensing range [mm]: | 3 |
Real sensing range Sr [mm]: | 3 ± 10 % |
Operating distance [mm]: | 0...2.43 |
Increased sensing range: | yes |
Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr]: | 1...15 |
Switch point drift [% of Sr]: | -10...10 |
Ambient temperature [°C]: | -40...85 |
Protection: | IP 65; IP 66; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on) |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
EN 55011: | class B |
Vibration resistance: | EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
EN 60068-2-6 Fc: | 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
Shock resistance: | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
EN 60068-2-27 Ea: | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
Continuous shock resistance: | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
EN 60068-2-27: | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
Fast temperature change: | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
EN 60068-2-14 Na: | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
Salt spray test: | EN 60068-2-52 Kb severity level 5 (4 test cycles) |
EN 60068-2-52 Kb: | severity level 5 (4 test cycles) |
MTTF [years]: | 1708 |
UL approval: | Ta -25...80 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL Approval no. A017 File number UL E174191 |
Ta: | -25...80 °C |
Enclosure type: | Type 1 |
voltage supply: | Limited Voltage/Current |
UL Approval no.: | A017 |
File number UL: | E174191 |
Weight [g]: | 15.5 |
Housing: | threaded type |
Mounting: | flush mountable |
Dimensions [mm]: | M8 x 1 / L = 30 |
Thread designation: | M8 x 1 |
Materials: | stainless steel (1.4404 / 316L); sensing face: LCP white; LED window: PEI; lock nuts: stainless steel (1.4404 / 316L) |
Tightening torque [Nm]: | A = 5 mm: 2 Nm; B: 5 Nm |
Display: | switching status 4 x 90° LED, yellow |
switching status: | 4 x 90° LED, yellow |
Accessories (supplied): | lock nuts: 2 |
Pack quantity: | 1 pcs. |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.02 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |