E30444
IO-Link repeater. IO-LINK REPEATER
IO-Link range increased up to 240 m. Series connection of max. 3 repeaters possible. Easy set-up with "plug & play". Transparent to all certified IO-Link masters. Use in the food and beverage industry
Special feature: | Gold-plated contacts |
Operating voltage [V]: | 18...30 DC |
Current consumption [mA]: | < 20 |
Protection class: | III |
Reverse polarity protection: | yes; (on the master side) |
Overvoltage protection: | yes; (integrated) |
Surge protection for voltage: | between L-, pin 5 and ground between L+, signal cables and ground Umax = 45 V for surge Umax = 90 V for surge Umin = 30 V for normal operation Umin = 60 V for normal operation |
between L-, pin 5 and ground: | between L+, signal cables and ground |
Umax = 45 V for surge: | Umax = 90 V for surge |
Umin = 30 V for normal operation: | Umin = 60 V for normal operation |
Surge protection for current: | surge current leakage current Imax = 25 A Imax = 10 µ |
surge current: | leakage current |
Imax = 25 A: | Imax = 10 µ |
Power-on delay time [s]: | < 2; (per repeater) |
Current rating per port [A]: | 0.84; (Port Class A; Port Class B: 2) |
Delay time acyclic data: | up to 2 cycles; (per repeater) |
Delay time process data: | up to 1 cycle; (per repeater) |
Communication interface: | IO-Link |
Unterstützte IO-Link Revision: | 1.0; 1.1 |
Unterstützte Masterportklasse: | A / B |
Transmission type: | COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud) |
SDCI standard: | IEC 61131-9 |
SIO mode: | no |
Ambient temperature [°C]: | -25...65 |
Storage temperature [°C]: | -40...85 |
Protection: | IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68) |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-4 in plastic or open metal tanks |
DIN EN 61000-6-4: | in plastic or open metal tanks |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 409 |
Weight [K40]: | 212.2 |
Materials: | stainless steel (1.4404 / 316L); PEI; PA reinforced fibre; FKM; Grounding clamp: stainless steel (1.4301 / 304) |
Display: | 1 x LED operation green IO-Link green fault red |
operation: | green |
IO-Link: | green |
fault: | red |
Remarks: | For information on the maximum cable length please refer to the operating instructions. functional grounding via premounted grounding clamp for further information please see the operating instructions |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
Port Class A: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.21 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |