Function: Amplifier
Supply Voltage: 15 – 30 V dc / 24 V ac
Sensing Range: 70 m
Sensitivity Adjustment: Manual
Output: Relay
Housing: Removable screw terminals
Supply Voltage: 24 V dc, 15 – 30 V dc or 24 V ac
Voltage Tolerance: +/– 10 %
Current Consumption: Max. 2,5 W
Response Time ton / toff, Relay: 35 ms / 35 ms
Output, Relay: 250 V ac/3 A, 120 V ac/5A
Alarm Output, Transistor: 12-30 V dc / 10 mA
Test Input: Yes
Power On Indicator: Green LED
Output Indicator: Yellow LED
LR Sensor Failure Indicator: Red LED
LT Sensor Failure Indicator: Red LED
Signal Level Indicator: Green LED
Sensor Monitor LED Drive: Green LED on the receiver: ‘Power ON’ Yellow LED on the transmitter: PA 15 output activated
Hysteresis: Approx. 45 %
Operation Frequency, Relay: 14 Hz
Housing Material: Polyamide
Operation Temperature: – 10 to +50 °C
Storage Temperature: – 40 to +80 °C
Sealing Class: IP 40

Logistische Daten

ECCN:
Ursprungsland:
EAN:
Gewicht: 0,00 kg
Länge: 0,00 m
Breite: 0,00 m
Höhe: 0,00 m