KA1420
KAS-80-A21/61-S-K-PEEK-3D, ATEX
Printing Industry. Capacitive sensors detect all kinds of inks:. Water based • solvent based • UV-Inks
Thread / Process connection: | M 8 x 1 |
Housing material active surface: | PEEK (FDA 21 CFR 177.2415) |
Housing material: | PEEK (FDA 21 CFR 177.2415) |
Housing material lid: | PA |
Electrical version: | 3-Leiter DC |
Operating current (Ie): | 0…150 mA |
Voltage drop max. (Ud): | ≤ 2 V |
Permitted residual ripple max.: | 10% |
Noload current (Io): | Typ. 15 mA |
Frequency of operating cycles max.: | 50 Hz |
LEDdisplay: | Gelb |
Protective circuit: | Eingebaut |
Degree of protection IEC 60529: | IP 67 (mit versiegelter Potentiometerschraube) |
Norm: | EN 60947-5-2 |
Media optimized: | JA |
Quattro Protect: | JA |
Sensing dinstance Sn: | produktberuehrend-mediumabhaengig-einstellbar |
Operating voltage: | 10…30 V DC |
Permitted ambient temperature min.: | -20 °C |
Permitted ambient temperature max.: | +70 °C |
Installation: | Nichtbündig |
Output function: | Schließer |
Output signal: | PNP |
Cable length: | 2 m |
Connection: | PUR-Kabel, 3 x 0,14 mm² |
CE: | JA |
RoHS: | JA |
ATEX product marking dust: | Ex II 3D IP67 T101° C X |
Certified Zones ATEX: | 3D |
MTTF: | 1780 Jahre |
WHG certification: | Auf Anfrage |
ECCN: | |
Ursprungsland: | |
EAN: | |
Gewicht: | 0,00 kg |
Länge: | 0,00 m |
Breite: | 0,00 m |
Höhe: | 0,00 m |