KA1409
KAS-80-26-A-K-160-G1/2"-PEEK-StEx, ATEX
Housing material PEEK with FDA certification. Also available are models that are constructed according to the EHEDG guidelines. ATEX Zone 20 Zone 1. PEEK G1/2. Capacitive Sensors – S26. Series 80 – PNP. Process connection: G 1/2“. Housing material: PEEK. For use in areas with the risk of dust explosion, zone 20. For use in areas with the risk of gas explosion, zone 1. Special version with flange. Sealing can be made with a gasket or PTFE-tape. Advantages:. EHEDG conform. Measurement is independent of the mounting position. Permitted pressure on the active area: 10 bar. Process connection G 1/2“. DMT 01 ATEX E 157 IECEx BVS 07.0015. II 2 G Ex mb IIC T4 Gb Ex mb IIC T4 Gb. II 1/2 D Ex ta/tb IIIC T101°C Da/Db Ex ta/tb IIIC T101°C Da/Db
Thread / Process connection: | G 1/2" |
Housing material active surface: | PEEK (FDA 21 CFR 177.2415) |
Housing material: | PEEK (FDA 21 CFR 177.2415) |
Housing material lid: | PC (FDA 21 CFR 177.1580) |
Electrical version: | 4-Leiter DC |
Operating current (Ie): | 2 x 0…150 mA |
Voltage drop max. (Ud): | ≤ 2 V |
Permitted residual ripple max.: | 10% |
Noload current (Io): | Typ. 15 mA |
Frequency of operating cycles max.: | 15 Hz |
LEDdisplay: | Grün / Gelb |
Protective circuit: | Eingebaut |
Degree of protection IEC 60529: | IP 67 (mit versiegelter Potentiometerschraube) |
Norm: | EN 60947-5-2 |
Media optimized: | JA |
Quattro Protect: | JA |
Sensing dinstance Sn: | produktberuehrend-mediumabhaengig-einstellbar |
Operating distance min. / max. adjustable: | 0…10 mm |
Operating voltage: | 10…30 V DC |
Permitted ambient temperature min.: | -25 °C |
Permitted ambient temperature max.: | +70 °C |
CIP / SIP: | CIP / SIP 121°C |
Installation: | Nichtbündig |
Output function: | Antivalent (S + Ö) |
Output signal: | PNP |
Cable length: | 2 m |
Connection: | PVC-Kabel, 4 x 0,34 mm² |
CE: | JA |
RoHS: | JA |
UL CSA certification: | JA |
ATEX product marking dust: | Ex II 1/2 D Ex ta/tb Ex IIIC T101°C Da/Db |
ATEX product marking gas: | Ex II 2G Ex mb Ex IIC T4 Gb |
Certified Zones ATEX: | 2G1/2D |
IECEX product marking dust: | Ex ta/tb IIIC T101°C Da/Db |
IECEX product marking gas: | Ex mb IIC T4 Gb |
MTTF: | 272,63 Jahre |
WHG certification: | Auf Anfrage |
ECCN: | |
Ursprungsland: | |
EAN: | |
Gewicht: | 0,00 kg |
Länge: | 0,00 m |
Breite: | 0,00 m |
Höhe: | 0,00 m |