7SSR24V/12M
Position control for low-play doors / casings on hazardous machinery. Contactless encoded electronic sensor with relay. Category 1 total safety management without an external controller according to EN954-1. According to ISO 13849-1 Type 4 according to ISO 14119. Level of performance without an external controller: PL = c. Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: | 1 Cycle before dangerous failure B10d = 2,000,000 at 100mA Max. activation distance 6 mm, 2 mm hysteresis Safety contacts/diagnostics 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding mono-code inviolable Indication LED indicating code absence Reset automatic Attachment 2 M30 nuts provided Mounting position 1 Material INOX316L Electrical connection 3, 6, 12m cable Water resistance IP 69K (Front side) IP67 (Rear side) Temperature -25°C to +60°C Marking label + serial no. for traceability |
ECCN: | |
Country of Origin: | |
EAN: | |
Weight: | 0.00 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |